Ince, IsmailBozdag, AliTosunlar, M. BahadirHatir, M. ErgunKorkanc, Mustafa2020-03-262020-03-2620181866-62801866-6299https://dx.doi.org/10.1007/s12665-018-7595-zhttps://hdl.handle.net/20.500.12395/36474Building stones have long been one of the most widely used construction materials in the world. Building stones used in historical monuments are deteriorated partly or completely depending on the environmental and atmospheric effects. In recent years, non-destructive test methods have been used to assess deterioration of building stones used in historical monuments. Godene stone is one of the building stones being widely used in the historical buildings in the Konya region, Central Anatolia. The most deterioration effects are observed in the Ferit PaAYa Cistern among the historical structures built with Godene stone in the region. The aim of this study is to assess the deteriorating effects in the street fa double dagger ade of the Ferit PaAYa Cistern via non-destructive testing methods (Schmidt hardness rebound value, P-wave velocity, humidity measurement and thermal imaging) and create maps of deteriorated features. Turkey's historic places are integrated to Turkish culture, efforts are made to conserve heritage through rehabilitation. Therefore, this study will help developers and federal managers during the project planning stage by providing technical data.en10.1007/s12665-018-7595-zinfo:eu-repo/semantics/closedAccessNon-destructive testFerit Pasa CisternDeteriorationGodene stoneKonyaDetermination of deterioration of the main facade of the Ferit PaAYa Cistern by non-destructive techniques (Konya, Turkey)Article7711Q2WOS:000434884900002Q3