Zengin, NazmiÖzkağnıcı, AhmetGündüz, KemalAkçam, Nurullah2020-03-262020-03-262001Zengin, N., Özkağnıcı, A., Gündüz, K., Akçam, N., (2001). Arka Kamara Intraoküler Lensli Olgularda Gonyoskopik Bulgular. Mn Oftalmoloji, 8(2), 125-128.1300-4786http://www.trdizin.gov.tr/publication/paper/detail/TVRVd09UYzM=https://hdl.handle.net/20.500.12395/17417AMAÇ: Ekstrakapsüler katarakt ekstraksiyonu ve arka kamara lens implantasyonu yapılan olgularda gonyoskopik muayene ile intraoküler lenslerin haptik biçimi ve yerleşim yeri farklılıklarının ön kamara açısındaki etkileri araştırıldı. GEREÇ VE YÖNTEM: Ekstrakapsüler katarakt ekstraksiyonu ve intraoküler lens implantasyonu yapılan 37 olgunun 40 gözü çalışmaya dahil edildi. Postoperatif takiplerde, iridokorneal açı Goldmann üç aynalı lensi kullanılarak değerlendirildi. Olguların takip süresi ortalama 6.20.6 ay (5-8 ay) idi. BULGULAR: Haptik üzerinde periferik anterior sineşi (PAS) modifiye C-lup arka kamara lensi implante edilen 20 gözün %45.0'inde, L-lup arka kamara lensi implante edilen 20 gözün ise %70.0'inde görüldü. Her iki grup arasındaki fark istatistiksel olarak anlamlı değildi (p 0.05). Her iki haptiğin siliyer sulkusda olduğu simetrik yerleşimli gözlerde haptik üzerinde PAS %53.3 gözde izlenirken, bir haptiğin sulkusda diğerinin kapsül içinde olduğu asimetrik yerleşimli olanlarda bu oran %70.0 idi. Her iki grup arasındaki fark anlamlı bulunmadı (p 0.05). Olguların hiçbirinde postoperatif dönemde göziçi basıncında artma olmadı. SONUÇ: Bu çalışmanın sonuçları modifiye C-lup ve L-lup İOL kullanımının ve bunların haptiklerinin siliyer sulkusa simetrik veya asimetrik yerleşmiş olmasının PAS oluşumuna yol açma bakımından farklı olmadığını düşündürmektedir.PURPOSE: To determine the effects of haptic shape and localization differences on the iridocorneal angle in patients which underwent extracapsular cataract extraction and intraocular lens implantation. MATERIAL AND METHODS: Forty eyes of 37 patients which underwent extracapsular cataract extraction and intraocular lens implantation were enrolled in the study. In postoperative follow-up, iridocorneal angle was assessed by the Goldmann three mirror lens. The mean follow-up period of the patients was 6.2±0.6 (5-8 ) months. RESULTS: Peripheric anterior synechia (PAS) over the haptic was observed in 45.0% of 20 eyes which were implanted a modified C-loop posterior chamber lens, and in 70.0% of 20 eyes which were a L-loop posterior chamber lens implanted. The difference between these groups was not statistically significant (p> 0.05). Whilst, PAS over the haptic was observed in 53.3% of eyes who had both haptics located in the ciliary sulcus symmetrically, this ratio was 70.0% in eyes who had one haptic in the sulcus and other in the capsular bag symmetrically. The difference between these two groups was not found to be statistically significant (p> 0.05). Increased intraocular pressure was not noted in any of the patients. CONCLUSION: The results of the present study suggested that using modified C-loop or L-loop and symmetric or asymmetric localization of their haptics on the ciliary sulcus are not different from each other in respect of inducing PAS formation.trinfo:eu-repo/semantics/closedAccessGöz HastalıklarıArka Kamara Intraoküler Lensli Olgularda Gonyoskopik BulgularGonioscopic Findings in Cases With Posterior Chamber Intraocular LensesOther82125128