Daghan, B2020-03-262020-03-2620050731-6844https://dx.doi.org/10.1177/0731684405052197https://hdl.handle.net/20.500.12395/19843The present study deals with the effects of combined internal pressures, temperatures, and moistures on filament-wound multilayered composite cylinders for the plane-strain case. The analysis accounts for the failure pressure for various orientation angles under hygrothermal conditions. The Tsai-Wu criterion is used for checking the first-ply failure of layers. The chosen orientation angles are 15, 30, 45, 60, and 75 degrees.en10.1177/0731684405052197info:eu-repo/semantics/openAccesscomposite cylindersmultilayered pipesfailure pressurefilament-woundPredicting the first-ply failure of multilayered composite cylinders under hygrothermal loadingArticle241717811789Q1WOS:000233337800001Q4