Yazar "Boz, Ismail" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Curcumin Modulates Muscle Damage but not Oxidative Stress and Antioxidant Defense Following Eccentric Exercise in Rats(VERLAG HANS HUBER, 2014) Boz, Ismail; Belviranli, Muaz; Okudan, NilselAim: The purpose of this study was to investigate the effects of curcumin on eccentric exercise-induced muscle damage and oxidative stress in rats. Methods: Thirty male Wistar rats were divided into four groups: Control (C; no curcumin, no exercise; n=6), Curcumin (Cur; n=8), Exercise (E; n=8) and Exercise Plus Curcumin (ECur; n=8). Curcumin was given for 20 days via oral gavage at doses of 200 mg/kg(-1) of body weight per day, dissolved in corn oil. On the 21st day eccentric exercise was provided via a treadmill run and the rats were sacrificed immediately after. Results: Eccentric exercise resulted in significant (p < 0.05) increases in all injury markers such as creatine kinase (CK) and myoglobin, but curcumin supplementation tended to decrease CK activity (p > 0.05) and significantly decreased myoglobin levels (p < 0.05). In blood and muscle samples, malondialdehyde (MDA) levels were not affected by either curcumin or exercise (p > 0.05). MDA levels in liver tissue decreased in the ECur group, compared to the control (p < 0.05). Superoxide dismutase (SOD) activities and glutathione (GSH) levels were affected by neither curcumin nor exercise (p > 0.05), in blood, muscle and liver tissues. Conclusion: The results of this study suggest that curcumin has a protective effect on eccentric exercise induced muscle damage, and that this effect might be independent of oxidative stress and antioxidant systems.Öğe Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol(PLEIADES PUBLISHING INC, 2014) Filik, Hayati; Cetintas, Gamze; Koc, Serkan Naci; Gulce, Handan; Boz, IsmailA Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop -casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5-200-M with differential pulse voltammetry (DPV) and the detection limit was 0.051-M. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determi- nation of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.