Yazar "Erdemir, A." seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study(WILEY, 2008) Tosun, G.; Erdemir, A.; Eldeniz, A. U.; Sermet, U.; Sener, Y.Aim To evaluate the accuracy of the Root ZX (J Morita Corp., Kyoto, Japan) and Tri Auto ZX (J Morita Corp.) devices for measuring root canal length in primary teeth with and without apical resorption. Methodology Thirty-four extracted human primary molar teeth with resorption and 19 primary teeth without resorption were collected. After endodontic access preparation, the actual lengths of the teeth were determined. The teeth were then embedded in an alginate model to determine the electronic working length measurement. Statistical evaluation was completed using Student's t-tests. Results For the Root ZX, there was no significant difference between those teeth with root resorption and those without. However, for the Tri Auto ZX, there was a significant difference in the electronic measurements between those teeth with root resorption and those without (P < 0.05). Significant differences were found amongst the measurements of the two apex locators (P < 0.05). For root canals with resorption, the respective accuracy rates (within +/- 0.5 mm) of Root ZX and Tri Auto ZX were 83.33% and 89.47%; within +/- 1 mm, the Root ZX and Tri Auto ZX demonstrated 98.95% and 100% accuracy, respectively. For root canals with no resorption, the percentage of measurements within +/- 0.5 mm of the apical construction was 89.28% for the Root ZX and 80.35% for the Tri Auto ZX. The accuracy within +/- 1 mm of the Root ZX and the Tri Auto ZX was 98.22% and 100%, respectively. Conclusion Within the limitations of this laboratory study, the presence of resorption affected the performance of the Tri Auto ZX more than the Root ZX.Öğe Effects of Endodontic Irrigation Solutions on the Microhardness and the Roughness of Root Canal Dentin.(Int Amer Assoc Dental Researchi a D R/a a D R , 2003) Arı, H.; Erdemir, A.; Belli, Sema[Abstract not Available]Öğe The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece(BLACKWELL PUBLISHING, 2007) Erdemir, A.; Eldeniz, A. U.; Ari, H.; Belli, S.; Esener, T.Aim To determine the influence of various irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. Methodology One hundred and forty teeth with single canals and mature apices, scheduled for extraction for either periodontal or prosthetic reasons in 76 patients were used. Following informed written consent local anaesthesia was administered, access cavities were prepared and pulp tissue removed. The teeth were then randomly divided into seven groups according to the irrigating solutions used. The root canal length measurements were completed using the Tri Auto ZX handpiece with automatic reverse function in the presence of one or other of the following solutions: 0.9% saline, 2.5% NaOCl, 3% H2O2, 0.2% chlorhexidine, 17% EDTA, Ultracaine((R)) D-S or in the absence of an irrigating solution (control). Files were immobilized in the access cavity with composite resin. After extraction, the apical regions of the teeth were exposed and the file tips examined under a stereomicroscope. Distances between the file tips and the apical constriction were measured (mm) and analysed using a one-way ANOVA and post hoc Tukey test. Results Mean distances from the apical constriction to the file tip were longer in the 0.9% saline group (P < 0.05). There was no statistically significant difference on file tip position between the other solutions. Conclusions Tri Auto ZX gave reliable results with all irrigating solutions apart from in the presence of 0.9% saline.