Yazar "Erdemir, Ali" seçeneğine göre listele
Listeleniyor 1 - 14 / 14
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Assessment of Antibacterial Activity of Endorez(Mosby-Elsevier, 2006) Eldeniz, Ayçe Ünverdi; Erdemir, Ali; Hadimli, Hasan Hüseyin; Belli, Sema; Erganis, OsmanObjective. The aim of this in vitro study was to evaluate antibacterial activity of a new resin based sealer, EndoREZ in comparison with 5 other sealers: AH 26, Diaket, Sultan, Apexit, and RoekoSeal. Study design. The effect of 6 different sealers oil the growth of 3 bacteria (Enterococcus faecalis, Staphylococcus aureus, and Pseudomonas aeruginosa) was measured using the agar diffusion test (ADT) and direct contact test (DCT). For ADT, 200 mu L bacterial suspensions were spread oil agar plates and freshly mixed sealers were applied to uniform wells punched in the agar. The zones of inhibition of bacterial growth were measured at 24 hours, 48 hours, 7 days, and 10 days. For DCT, 2 sets of sealers were prepared: fresh and 24-hour samples. Fresh samples were used within 20 minutes of mixing time while 24-hour samples were allowed to set it) a humid atmosphere at 37 degrees C for 24 hours before testing. Sealers were mixed and placed oil the walls of microliter plate wells and 10-mu L bacterial Suspensions were allowed to directly contact the sealers for I hour. Fresh media were added and 15 mu L were transferred from this plate to another plate containing fresh medium (215 mu L). Bacterial growth of this last plate was then measured using spectrophotometer every hour over 16 hours. Results. ADT results indicated that EndoREZ, Apexit, and RoekoSeal did not show any, antibacterial activity. In DCT results, AH 26 and Sultan were potent bacterial growth inhibitors. Conclusion. EndoREZ is not as potent a bacterial growth inhibitor as Sultan and AH 26.Öğe Comparison of Apical Transportation and Canal Straightening Between Protaper Next, Hyflex, Reciproc and Reciproc Blue Instruments(Selçuk Üniversitesi, 2022) Türkyilmaz, Ali; Erdoğan, Deniz; Dinçer, Gözde Akbal; Erdemir, AliBackground: This study aimed to compare apical transportation and canal straightening of ProTaper Next, HyFlex Electric Discharge Machining, Reciproc and Reciproc Blue nickel-titanium (NiTi) files with different apical enlargements. Methods: Forty-eight mandibular molar human teeth were included in the study. The teeth were divided into four groups according to the NiTi file types (n=12). A digital radiographic method was used to compare apical transportation and canal straightening in the buccolingual and mesiodistal directions using before-and-after images superimposed with Image J software. The Kruskal-Wallis test with Bonferroni correction and the Wilcoxon test were used; the P value was set at 5%. Results: The maximum transportation of the buccolingual and mesiodistal directions were 0.216 mm and 0.196 mm with Reciproc file. The maximum straightening of the buccolingual and mesiodistal directions were degrees of 8.661 and 8.048 respectively with ProTaper Next and Reciproc files. Conclusion: ProTaper Next, HyFlex Electric Discharge Machining and Reciproc Blue filespresented similar results. Using a larger instrument increased the apical transportation and canal straightening.Öğe Çözücüye Daldırılarak Şekillendirilmiş Guta-Perka Tekniğinde Kloroform ve Halotan ile Elde Edilen Apikal Sızdırmazlıkların Karşılaştırılması(2002) Erdemir, Ali; Üngör, MeteBu çalışmanın amacı, kloroform ve halotan gibi iki farklı çözücüye daldırılarak şekillendirilmiş guta - perka tekniğinin oluşturduğu apikal sızıntıyı karşılaştırmaktı. Bu çalışmada 57 adet tek köklü insan dişi kullanıldı. Kanal preparasyo-nunu takiben, her grupdan örnekler kanal dolgu patı olarak AH Plus kullanılarak kloroforma daldırılmış, halotana daldırılmış veya hiç çözücü uygulanmamış gutta perkanın lateral kondensas-yonu tekniğiyle dolduruldular. Yedi gün 37C de % 100 nemli ortamda saklandıktan sonra, dişler 24 saat 100 mmHg vakum altında metilen mavisi boyasına bırakıldı. Bundan sonra dişler dik olarak kesilip ikiye ayrıldı ve boya penetrasyonu lineer olarak stereomikroskopla ölçüldü. Kloroform ve halotan grupları arasında istatistiksel olarak önemli bir fark yokken (P0,05), her iki çözücüye daldırma tekniği de geleneksel lateral kondensasyon grubundan önemli derecede daha az boya sızıntısı gösterdi (P0,05).Öğe "Çözücüye daldırılarak şekillendirilmiş güta-perka" tekniğinde kullanılan kloroform ve halotanın, güta-perkanın biyolojik uyumluluğuna ve apikal sızdırmazlığına etkisi(Selçuk Üniversitesi Sağlık Bilimleri Enstitüsü, 2002) Erdemir, Ali; Üngör, MeteÇalışma iki bölümde gerçekleştirildi. Biouyumluluk çalışması in vivo şartlarda yapılırken, apikal mikrosızıntı in vitro olarak değerlendirildi. İn vivo çalışmanın amacı, çözücüye daldırılarak sıkıştırılan guta-perka tekniğinde kullanılan chloroform ve halotanın biouyumluluğunu değerlendirmekti. Yirmi sekiz adet Spraque Dawley cinsi rat kullanıldı. Chloroform ve halotana daldırılan guta-perka içeren teflon tüpler ratların sırt bölgesindeki subkutanöz konnektif dokusuna implante edildi. Guta-perka ve boş teflon tüp her rata kontrol amacıyla implante edildi. Her rata farklı gruplardan dört implantasyon yapıldı. Gözlem periyotlarından sonra (24 saat, 1, 4 ve 8 hafta) ratlar histolojik analiz için öldürüldü. Çalışmanın sonuçları 1 gün sonra tüm implant tipleri için inflamatuar reaksiyonların hafif ve orta derecede olduğunu gösterdi. Reaksiyonların derecesi, 1 hafta sonra orta ve şiddetliye doğru arttı ve 4 ve 8. haftalardan sonra azaldı. 8 hafta sonunda tüm implant tipleri için minimal ve hafif inflamatuar reaksiyonlar vardı. Chloroform ve halotana daldırılan guta-perka ve kontrol guta-perka ve teflonla oluşan histopatolojik doku reaksiyonları arasında belirgin bir farklılık olmadığı görüldü. Çalışmanın ikinci aşamasında, in vitro çalışmanın amacı kloroform ve halotan gibi iki farklı çözücüye daldırılarak şekillendirilmiş guta-perka tekniğinin oluşturduğu apikal 46 sızıntıyı karşılaştırmaktı. Bu çalışmada 57 adet tek köklü insan dişi kullanıldı. Kanal preparasyonunu takiben, her gruptan örnekler kanal dolgu patı olarak AH Plus kullanılarak kloroforma daldırılmış, halotana daldırılmış veya hiç çözücü uygulanmamış gutta perkanın lateral kondensasyonu tekniğiyle dolduruldular. Yedi gün 37°C de %100 nemli ortamda saklandıktan sonra, dişler 24 saat 100 mmHg vakum altında metilen mavisi boyasına bırakıldı. Bundan sonra dişler dik olarak kesilip ikiye ayrıldı ve boya penetrasyonu lineer olarak stereomikroskopla ölçüldü. Kloroform ve halotan grupları arasında istatistiksel olarak önemli bir fark yokken (p>0,05), her iki çözücüye daldırma tekniği de geleneksel lateral kondensasyon grubundan önemli derecede daha az boya sızıntısı gösterdi.Öğe Effect of Different Cavity Disinfectants on Shear Bond Strength of Composite Resin to Dentin(QUINTESSENCE PUBLISHING CO INC, 2009) Ercan, Ertuğrul; Erdemir, Ali; Zorba, Yahya Orçun; Eldeniz, Ayce Ünverdi; Dallı, Mehmat; İnce, Bayram; Kalaycıoğlu, BarışPurpose: The aim of this study was to evaluate the effect of different cavity disinfectants on dentin bond strengths of composite resin applied with two different adhesive systems. Materials and Methods: One hundred mandibular third molars were sectioned parallel to the occlusal surface to expose midcoronal dentin. The dentin surfaces were polished with waterproof-polishing papers The specimens were randomly divided into 5 groups of 20 each. In group 1, the specimens were not treated with any cavity disinfectants and served as control. From groups 2 to 5. dentin surfaces were treated with the following cavity disinfectants, respectively; 2% chlorhexidine solution, 2.5% NaOCl, 1% chlorhexidine gel, 3% H2O2. The specimens were then randomly divided into 2 subgroups including ten teeth each to evaluate the effect of different bonding systems Dentin bonding systems were applied to the dentin surfaces and the composite buildups were created After the specimens were stored in an incubator for 24 h. the shear bond strength was measured at a crosshead speed of 1 mm/min. The bond strength data were analyzed with one way analysis of variance and Tukey-HSD tests. Results: There was no significant difference between chlorhexidine gel and control groups regardless of the type of the bonding agent (p > 0.05). On the other hand, pretreatment with NaOCl, H2O2 or chlorhexidine solutions had a negative effect on the shear bond strength of self-etching bonding systems Conclusion: The findings of this study suggest that when NaOCl, H2O2 or chlorhexidine solution Eire used as a cavity disinfectant, an etch-and-rinse bonding system should be preferredÖğe Effect of temporary filling materials on repair bond strengths of composite resins(WILEY-LISS, 2008) Erdemir, Ali; Eldeniz, Ayce Unverdi; Belli, SemaEndodontic access cavities sometimes can be prepared through a permanent composite restoration. Between the appointments, temporary cements are used to seal access cavities and may have negative effect on bonding of further composite restoration. The purpose of this study was to compare shear bond strength of composite to composite which had been in contact with various temporary filling materials. Standard cavities were prepared on 160 acrylic resin blocks, obturated with composite resin (Clearfil AP-X, Kuraray, Japan) and randomly divided into eight groups (n = 20). Group 1 received no treatment. From group 2-8, composite surfaces were covered with the following cements temporarily: Zinc-oxide/calcium-sulphate (Cavit-G, ESPE, Germany), two different Zinc-Oxide-Eugenol materials (ZnOE, Cavex, Holland and IRM, Dentsply, USA), Zinc-phosphate cement (Adhesor, Spofa-Dental, Germany),Zinc-polycarboxylate cement(Adhesor-Carbofine,Spofa-Dental, Germany), Glass-Ionomer-Cement (Argion-Molar, Voco, Germany), or light curing temporary material (Clip, Voco, Germany). The cements were removed mechanically after 1 week storage in distilled water at 37 degrees C and composite surfaces were treated with a self-etch adhesive system (SE-Bond, Kuraray, Japan). Composite resin build-ups were created on composite surfaces. Shear bond strength values were measured using universal testing machine at crosshead speed of 1 mm/min. The data was calculated in MPa and statistically analyzed using one-way ANOVA and Tukey tests. Eugenol-containing cements significantly reduced shear bond strengths of composite to composite (p < 0.05), while the other temporary materials had no adverse effect on shear bond strength (p > 0.05). These findings suggested that temporary filling materials except eugenol-containing materials have no negative effect on composite repair bond strengths. (c) 2007 Wiley Periodicals, Inc.Öğe Effects of Different Curing Units and Luting Agents on Push-out Bond Strength of Translucent Posts(Elsevier Science Inc, 2010) Zorba, Yahya Orçun; Erdemir, Ali; Türkyılmaz, Ali; Ünverdi Eldeniz, AyçeIntroduction: The aim of this study was to evaluate the effects of different curing units and 2 luting cements on the push-out bond strength of a translucent fiber post. Methods: Thirty maxillary incisor roots were endodontically treated. Post spaces were prepared, and the smear layers were removed. Posts (FRC Postec Plus) were luted with either a self-etch cement (Panavia F 2.0) or a self-adhesive cement (Maxcem). Luting agents were then light-activated with a quartz-tungsten-halogen, a blue light emitting diode, or a plasma-arc curing unit. Roots/cemented posts were transversally sectioned from coronal to apical. Push-out tests were performed, and data were analyzed by using three-way analysis of variance and Tukey tests. Results: Push-out bond strengths were significantly affected by the type of luting agent (P < .05) and root region (P < .05). The type of light source used in curing did not affect push-out bond strengths (P > .05). Conclusions: Self-adhesive resin cement provided higher bond strength than the self-etch cement when smear layer was removed before the post cementation. The push-out bond strength in the apical portion of the root was significantly lower than in the coronal region. The use of different curing units in the photoirradiation of dual-cured resin cement did not affect the retention of the fiber post as a result of the limited light transmission capability of this post.Öğe The effects of three different desensitizing agents on the shear bond strength of composite resin bonding agents(ELSEVIER SCIENCE BV, 2010) Zorba, Yahya Orçun; Erdemir, Ali; Ercan, Ertuğrul; Eldeniz, Ayce Ünverdi; Kalaycıoğlu, Barış; Ülker, MustafaThe aim of this study was to evaluate the effects of three desensitizing agents on the shear bond strengths of four different bonding agents used to bond composite resin to dentin. A total of 160 extracted human molars were sectioned parallel to the occlusal plane under water cooling, polished and randomly divided into 4 groups of 40. Each group was treated with a different desensitizing agent (Tooth Mousse, Ultra-EZ, Cervitec Plus), except for an untreated control group. Each group was then randomly subdivided into 4 groups of 10, and a different dentin bonding agent (XP Bond, AdheSE, Adper Prompt L-pop, GBond) was applied to each group in order to bond the specimens to a resin composite (Gradia Direct) built up using a plastic apparatus. A Universal Testing Machine was used to measure the shear bond strength of each specimen. Statistical analysis was performed using one-way ANOVA and Tukey's tests. With the exception of the Control/AdheSE and Ultra-EZ/XP Bond groups, no statistically significant differences were found in the shear bond strength values of the groups tested. These findings suggest that the use of different desensitizing agents does not affect the shear bond strength of various adhesive systems used to bond resin composite to dentin. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.Öğe Endodontide ozonun kullanımı(Selçuk Üniversitesi, 2020) Erdoğan, Deniz; Erdemir, AliOzon, oksitleyici özelliğinden dolayı uzun yıllardan beri tıp ve diş hekimliği alanlarında başarıyla kullanılan mükemmel bir antimikrobiyal ajandır. Ozon oral dokulara; ozon gazı, ozonlu su ve ozonlu yağ olarak uygulanabilir. Ozonun endodontide; irrigasyon solüsyonu, antimikrobiyal ajan, kanal içi medikament olarak kullanımı, ayrıca dental adezivlere ve postoperatif ağrı kontrolüne etkisi de gözden geçirilmiştir. Bu derlemenin amacı; ozonun etkileri ve endodontideki kullanım alanlarına yönelik fikir vermektir.Öğe Evaluation of pH and calcium ion release of Acroseal sealer in comparison with Apexit and Sealapex sealers(MOSBY-ELSEVIER, 2007) Eldeniz, Ayce Unverdi; Erdemir, Ali; Kurtoglu, Firuze; Esener, TimurObjective. This is an in vitro assessment of pH level and calcium ion release exhibited by 3 calcium hydroxide-based root canal sealers-Sealapex, Apexit, and Acroseal. Study design. The materials were prepared according to the manufacturers' instructions and placed in 1 cm long and 4 mm diameter tubes. The tubes were then immersed in a glass flask containing 10 mL bidistilled water (n = 15), which was sealed and stored at 37 degrees C before the materials had set. The control group contained bidistilled water with empty tubes (n = 12). At predetermined time intervals (24 h, 96 h, and 7, 15, and 28 days) the pH of the bidistilled water was tested with a pH meter and for released calcium by using spectrophotometry. The data were statistically analyzed using 1-way analysis of variance for the comparison of the materials at each time point. If the difference was significant, individual comparisons were performed by Tukey multiple comparisons test (alpha = .05). Results. Sealapex produced higher pH and released significantly higher calcium amounts than the other 2 sealers at all periods (P < .05). Apexit showed higher calcium release than Acroseal at the end of 15 days (P < .05). There was no significant difference in the pH between Apexit and Acroseal (P > .05). Conclusion. The new Acroseal sealer presented the least calcium ion release and pH than Sealapex and less calcium ion release than Apexit sealer.Öğe Farklı Bonding Sistemlerin Kompozit Rezinin Amalgama Bağlanma Dayanımı Üzerine Etkisi(2005) Erdemir, Ali; Eldeniz, Ünverdi Ayşe; Arı, Hale; Belli, SemaAmaç: Restorasyonların onarımı, yenileme işlemine göre dis dokularına gelecek travmayı azaltma, sağlıklı dis dokularını koruma, hasta koltuğunda geçen süreyi azaltma ve daha ekonomik olma gibi avantajlara sahiptir. Bu çalışmanın amacı farklı bonding sistemler kullanılarak kompozit rezinin amalgam restorasyona bağlanma dayanımının in vitro olarak değerlendirilmesidir. Gereç ve Yöntem: 5x2.5 cm uzunluğunda 60 adet ahilik rezin blok hazırlandı. Bu bloklar üzerinde 5 mm çapında ve 3 mm derinliğinde kaviteler açıldı ve bu kaviteler amalgam ile dolduruldu. 24 saat bekletildikten sonra restorasyon yüzeyleri 600, 800 ve 1200 nolu su zımparasıyla zımparalandı. Örnekler her biri 15 örnek içeren 4 gruba rastgele dağıtıldı. Her grupta amalgam yüzeyi farklı bir adeziv sistem (SE Bond, Prime & Bond NT, AQ Bond, İ-Bond) ile üretici firma önerileri doğrultusunda hazırlandı ve 2.38 mm çapında ve 3 mm uzunluğundaki silindirik şekilli plastik matriks içerisine kompozit rezin sıkıştırılarak yerleştirildi. 40 saniye ışık ile polimerizasyonu sağlandı. 24 saat sonra her örneğin makaslama kuvvetlerine karşı bağlanma dayanımı lmmldak hızla universal test makinesinde ölçüldü. Bağlanma dayanım değerleri Megapaskal olarak hesaplandı ve sonuçlar istatistiksel olarak Kruskal Wallis tek yönlü Varyans ve Tııkey testi kullanılarak analiz edildi. Bulgular: SE Bond diğer bonding sistemlerine göre daha yüksek dayanımı gösterdi (p0.05). AQ Bond ve 1-Bond sistemlerinin bağlanma dayanımları arasında.ise istatistiksel olarak önemli bir fark bulunamadı (p0.05). Sonuç: Sonuç olarak SE Bond amalgam restorasyonların kompozit rezinle tamirinde en yüksek bağlanma dayanımı göstermiştir.Öğe In Vitro Antibacterial Activity of a New Resin-Based Sealer(Int Amer Assoc Dental Researchi a D R/a a D R, 2003) Erdemir, Ali; Eldeniz, Ayçe Ünverdi; Hadimli, Hasan Hüseyin; Belli, Sema; Erganiş, Osman[Abstract not Available]Öğe The Effect of XP-endo Finisher R and PIPS Technique Using Er: YAG Laser on Removal of Gutta-percha in Root Canals Obturated with Two Different Obturation Techniques(Selçuk Üniversitesi, 2024) Akbal Dinçer, Gözde; Türkyılmaz, Ali; Hançerlioğulları, Dilek; Ermiş, Gülşen; Erdemir, AliBackground: The purpose of this study is to compare the efficacy of XP-endofinisher R file and PIPS technique using Er: YAG laser on gutta-percha removalin root canals obturated with two obturation techniques.Methods: The root canals of sixty single-rooted teeth were prepared withProTaper Next Rotary instruments up to X3 (Dentsply, Ballaigues,Switzerland). Half of the root canals were obturated with cold lateralcondensation technique and the other half with System B technique (KerrCorporation, CA, USA) and BioRoot RCS sealer (Setodent, Louisville, USA) wasused in all groups as a root canal sealer. After one week, all samples wereretreated with Protaper Universal retreatment instruments (DentsplyMaillefer, Ballaigues, Switzerland) and enlarged to ProTaper Next X5 File atthe working length. Both groups were divided into 3 subgroups according tothe additional cleaning methods: control group without an additionalcleaning method, XP-endo Finisher R or PIPS technique using Er: YAG laser.Finally, all teeth were split longitudinally and images were taken using anoperation microscope (Carl Zeiss, Heidelberg, Germany). The images wereanalyzed by Image J program. Two-way ANOVA and Tukey tests were usedfor statistical analysis.Results: There was a statistically significant difference between the canalfilling techniques applied in the evaluation of remnants (p=0.010). There wasno significant difference between additional cleaning methods (p=0.196).Conclusion: Within the limitations of this study, cleanliness is more difficultin root canals obturated with System B technique. Use of additional cleaningmethod was not effective in removal of root canal filling materials.Öğe Üç farklı bağlayıcı ajan ile uygulanan kompozit rezin kor materyalinin kron dentinine makaslama bağlanma dayanımlarının in vitro değerlendirilmesi(2005) Eldeniz, Ünverdi Ayçe; Erdemir, Ali; Belli, SemaAmaç: Bu çalışmanın amacı Photocore kompozit rezin kor materyalinin farklı üç tip dentin bağlayıcı ajan kullanılarak çürükten etkilenmiş ve sağlam dentine in vitro shear bağlanma dayanımının değerlendirilmesidir. Gereç ve Yöntem: Bu çalışmada altmış adet çekilmiş alt büyük azı kullanıldı. Bunların 30 adedinde koronal bölgede okluzal çürük vardı. Kronların 113'ü düşük hızlı elmas separe yardımıyla su soğutması altında kesildi. Örnekler soğuk ahilik rezin içerisine gömüldü. Çürükten etkilenmiş dentin örnekleri çürük teşhis edici boyama yöntemleri kullanılıp, uygun aşındırma işlemleri yapılarak hazırlandı. Dentin yüzeyleri 600, 800 ve 1200 numaralı şu zımparalarıyla zımparalandı. Sonra her grup her biri 10 örnek içeren üç alt gruba ayrıldı. Kor materyali dentin yüzeyine 2.3798 mm çapındaki ve 3 mm uzunluğundaki silindirik şekilli plastik matriks içine sıkıştırılarak yerleştirildi. Örnekler bir hafta 37 C'de ve %IOO nemde bekletildikten sonra, shear bağlanma dayanımları lmmldak hızla universal test makinası kullanılarak ölçüldü. Bağlanma dayanım değerleri megapaskal olarak hesaplandı ve sonuçlar istatistiksel olarak iki yönlü varyans, tek yönlü varyans ve Tukey HSD testleri kullanılarak analiz edildi. Bulgular: Farklı adezivlerin çürükten etkilenmiş dentine bağlanma dirençleri arasında önemli farklılık bulundu (p0.05). Tüm adeziv sistemler çürüklü dentinde daha düşük bağlanma dayanımı gösterdiler. Sonuç: Clearfil Photocore ile restore edilen örneklerde kullanılan Clearfil SE Bond, hem çürükten etkilenmiş, hem de normal dentinde en güçlü adezyonu gösterdi.