Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ersoy, Reyhan Ünlü" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules
    (AVES, 2012) Gümüş, Mehmet; Çay, Nurdan; Algın, Oktay; İpek, Ali; Ersoy, Reyhan Ünlü; Belenli, Olcay; Uğraş, Serdar
    PURPOSE To compare 21 and 27 gauge (G) needles used for fine-needle aspiration (FNA) of thyroid nodules to obtain better specimens for adequacy and cytological diagnosis. MATERIALS AND METHODS One hundred patients with thyroid nodules (100 nodules) were included in this study. Each nodule was aspirated with both 27 G and 21 G needles. The obtained aspirates were classified as adequate and inadequate by two separate cytopathologists. The results were analyzed by appropriate statistical methods. RESULTS There was no statistically significant difference between 21 G and 22 G needles in terms of adequacy, according to each pathologist (P > 0.05). After pathological evaluation with consensus, the adequacy prevalence was the same (84%) for both needle types in all study populations (P> 0.05). According to the ultrasound characteristics of nodules, the prevalence of inadequate samples in patients with hypoechoic or heterogeneous nodules was significantly higher compared with the prevalence of inadequate samples in patients with isoechoic or hyperechoic nodules for both types of needles (P < 0.05). However, according to the size of the needles, there was no significant difference between hypoechoic and heterogeneous nodules or between isoechoic and hyperechoic nodules with regard to the ability to yield adequate samples (P> 0.05). CONCLUSION The results of our study showed that FNA with 27 G needles can aspirate adequate material for cytopathological diagnosis. The probability of inadequate sample aspiration of hypoechoic and heterogeneous nodules is higher than that for other nodule types.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim