Yazar "Kalkan, Yildiray" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Effects of exposure to 2100 MHz GSM-like radiofrequency electromagnetic field on auditory system of rats(ASSOC BRASILEIRA OTORRINOLARINGOLOGIA & CIRURGIA CERVICOFACIAL, 2017) Celiker, Metin; Ozgur, Abdulkadir; Tumkaya, Levent; Terzi, Suat; Yilmaz, Mustafa; Kalkan, Yildiray; Erdogan, EnderIntroduction: The use of mobile phones has become widespread in recent years. Although beneficial from the communication viewpoint, the electromagnetic fields generated by mobile phones may cause unwanted biological changes in the human body. Objective: In this study, we aimed to evaluate the effects of 2100 MHz Global System for Mobile communication (GSM-like) electromagnetic field, generated by an electromagnetic fields generator, on the auditory system of rats by using electrophysiological, histopathologic and immunohistochemical methods. Methods: Fourteen adult Wistar albino rats were included in the study. The rats were divided randomly into two groups of seven rats each. The study group was exposed continuously for 30 days to a 2100 MHz electromagnetic fields with a signal level (power) of 5.4 dBm (3.47 mW) to simulate the talk mode on a mobile phone. The control group was not exposed to the aforementioned electromagnetic fields. After 30 days, the Auditory Brainstem Responses of both groups were recorded and the rats were sacrificed. The cochlear nuclei were evaluated by histopathologic and immunohistochemical methods. Results: The Auditory Brainstem Responses records of the two groups did not differ significantly. The histopathologic analysis showed increased degeneration signs in the study group (p = 0.007). In addition, immunohistochemical analysis revealed increased apoptotic index in the study group compared to that in the control group (p = 0.002). Conclusion: The results support that long-term exposure to a GSM-like 2100 MHz electromagnetic fields causes an increase in neuronal degeneration and apoptosis in the auditory system. (C) 2016 Associacao Brasileira de Otorrinolaringologia e Cirurgia Cervico-Facial. Published by Elsevier Editora Ltda.Öğe Sciatic nerve injury following analgesic drug injection in rats: A histopathological examination(KARE PUBL, 2018) Bostan, Habib; Cabalar, Murat; Altinay, Serdar; Kalkan, Yildiray; Tumkaya, Levent; Kanat, Ayhan; Balik, SabriOBJECTIVE: Sciatic nerve neuropathy can be observed following intramuscular gluteal injections. The histopathological examination of sciatic nerve damage following intramuscular injection in the gluteal region for acute pain treatment is not feasible in humans due to the inability to dissect and examine the nerve tissue. To overcome this issue, we used a rat model for demonstrating damage to the sciatic nerve tissue after the application of commonly used drug injections. METHODS: We investigated possible damage following the intramuscular injection of diclofenac, lornoxicam, morphine, and pethidine in a rat model based on histopathological characteristics such as myelin degeneration, axon degeneration, epineurium degeneration, fibrosis, epineurium thickening, perineurium thickening, lymphocyte infiltration, vacuolization, and edema. RESULTS: All the analgesic drugs used in our study induced histopathological changes in the sciatic nerve. Anti-S100 positivity, showing nerve damage, was found to be the lowest in the group treated with diclofenac. Neurotoxic effects of diclofenac on the sciatic nerve were greater than those of the other drugs used in the study. Lornoxicam induced the least histopathological changes in the nerve. CONCLUSION: Diclofenac induced severe nerve damage not only after direct injection in the sciatic nerve but also after injection in the area around the nerve. Thus, we recommend restricting the use of intramuscular gluteal injections of diclofenac. Intramuscular use of morphine and pethidine should also be overviewed.