Yazar "Kocak, Izzet" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Electrodialytic removal of fluoride from water: Effects of process parameters and accompanying anions(ELSEVIER, 2008) Ergun, Erdem; Tor, Ali; Cengeloglu, Yunus; Kocak, IzzetThe removal of fluoride from water by using electrodialysis with SB-6407 anion exchange membrane was tested at different current densities. After the determination of the optimum pH of feed phase under Donnan dialysis condition which gave the maximum transport of fluoride, the effect of mono- and bi-valent ions, such as chloride and sulphate, in the feed phase on the removal was investigated by electrodialysis. The transport of fluoride was also correlated with the flux data and explained according to structure of membrane. It was found that the removal of fluoride was higher in the absence of mono- and bi-valent ions. The reducing effect of sulphate ions on the transport of fluoride was higher than that of chloride ions, which was explained by considering interaction of both chloride and sulphate ions with the ionic group in the membrane and activity coefficient of fluoride in the presence of mono- and bi-valent ion set. Moreover, transport of fluoride increased with increasing current density and feed phase concentration. As the driving ion, the chloride ion is more efficient than the sulfate ion. Application of electrodialysis was carried out on the real water containing 20.6 mg/L of fluoride. Despite the presence of chloride and sulphate in real water sample, fluoride concentration could be reduced to 0.8 mg/L (96% removal), which was lower than World Health Organization (WHO) standard (1.5 mg/L. (C) 2008 Elsevier B.V. All rights reserved.Öğe Removal of boron from water by using reverse osmosis(ELSEVIER SCIENCE BV, 2008) Cengeloglu, Yunus; Arslan, Gulsin; Tor, Ali; Kocak, Izzet; Dursun, NesimThe removal of boron from water was investigated by using reverse osmosis (110) technique with SWHR, BW-30 (FILMTEC) and AG (GE Osmonics) membranes, not considered :previously. The effect of pH and concentration of the feed water and operating pressure on the boron rejection was investigated. The experimental results indicated that boron rejection mostly depends on membrane type, pH of the feed water and operating pressure. The results also showed that boron car. be effectively removed only at feed water pH of 11. The lowest permeate boron concentration (the highest rejection, close to 99%) was obtained when SWHR membrane was used. The rejection efficiency of the membranes was found to be in the order of SWHR > BW-30 > AG. For all membranes, boron rejection increased with increasing operating pressure. Finally, two different natural (ground) water samples containing 24.8 and 9.4 mg/L of boron were treated by using RO with SWHR membrane and obtained results showed that RO could be efficiently used (with >95% rejection) for removal of boron from groundwaters. (C) 2008 Elsevier B.V. All rights reserved.