Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kurtoglu, M. G." seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Evaluation and Comparison of Three Different Anti-hepatitis C Virus Antibody Tests based on Chemiluminescence and Enzyme-linked Immunosorbent Assay Methods used in the Diagnosis of Hepatitis C Infections in Turkey
    (SAGE PUBLICATIONS LTD, 2009) Kesli, R.; Ozdemir, M.; Kurtoglu, M. G.; Baykan, M.; Baysal, B.
    The routine diagnosis of hepatitis C virus (HCV) infection is based on the detection of anti-HCV antibodies by two main methods (enzyme immunoassay [EIA] and chemiluminescence immunoassay [CIA]) but false-positives are a problem. We investigated three anti-HCV tests: two CIAs (Cobas (R) e 601 and Architects i2000SR); and one EIA (Ortho (R) HCV 3.0). Two other anti-HCV tests were also performed as supplementary and confirmatory tests, respectively: a recombinant strip immunoblot assay (RIBA HCV 3.0 SIA) and a reverse transcriptase polymerase chain reaction-based assay for HCV-RNA. After discriminating the false-positive results, the true anti-HCV seropositivity rate in 7156 serum samples was 0.91%. The seropositivity and false-positive rates for the Cobas (R) e 601, Architects i2000SR and Ortho (R) HCV 3.0 anti-HCV tests were 1.9% and 0.99%, 1.2% and 0.29%, and 0.87% and 0.01%, respectively. The mean level of HCV-RNA was 3399 x 10(3) IU/ml. Critical levels for false-positivity for HCV-RNA were a cut-off index of 200 for Cobas (R) e 601, a signal/cut-off (S/CO) of 5 for Architects i2000SR and an S/CO of 1.2 for Ortho (R) HCV 3.0. Positive and negative results for the RIBA HCV 3.0 SIA assay all accorded with the HCV-RNA assay, except for 23 (17%) 'indeterminate' results, all of which were negative with the HCV-RNA assay. In conclusion, to eliminate doubts related to false-positive findings in the initial HCV screening tests, additional confirmatory HCV-RNA assay should be performed.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim