    Öğe
    Novel application software for the semi-automated analysis of ınfrared meibography ımages
    (LIPPINCOTT WILLIAMS & WILKINS, 2019) Shehzad, Danish; Gorcuyeva, Sona; Dag, Tamer; Bozkurt, Banu
    Purpose: To develop semi-automated application software that quickly analyzes infrared meibography images taken with the CSO Sirius Topographer (CSO, Italy) and to compare them to the manual analysis system on the device (Phoenix software platform). Methods: A total of 52 meibography images verified as high quality were used and analyzed through manual and semi-automated meibomian gland (MG) detector software in this study. For the manual method, an experienced researcher circumscribed the MGs by putting dots around grape-like clusters in a predetermined rectangular area, and Phoenix software measured the MG loss area by percentage, which took around 10 to 15 minutes. MG loss was graded from 1 (<25%) to 4 (severe >75%). For the semi-automated method, 2 blind physicians (I and II) determined the area to be masked by putting 5 to 6 dots on the raw images and measured the MG loss area using the newly developed semi-automated MG detector application software in less than 1 minute. Semi-automated measurements were repeated 3 times on different days, and the results were evaluated using paired-sample t test, Bland-Altman, and kappa kappa analysis. Results: The mean MG loss area was 37.24% with the manual analysis and 40.09%, 37.89%, and 40.08% in the first, second, and third runs with the semi-automated analysis (P < 0.05). Manual analysis scores showed a remarkable correlation with the semi-automated analysis performed by 2 operators (r = 0.950 and r = 0.959, respectively) (P < 0.001). According to Bland-Altman analysis, the 95% limits of agreement between manual analysis and semi-automated analysis by operator I were between -10.69% and 5% [concordance correlation coefficient (CCC) = 0.912] and between -9.97% and 4.3% (CCC = 0.923) for operator II. The limit of interoperator agreement in semi-automated analysis was between -4.89% and 4.92% (CCC = 0.973). There was good to very good agreement in grading between manual and semi-automated analysis results (kappa 0.76-0.84) and very good interoperator agreement with semi-automated software (kappa 0.91) (P < 0.001). Conclusions: For the manual analysis of meibography images, around one hundred dots have to be put around grape-like clusters to determine the MGs, which makes the process too long and prone to errors. The newly developed semi-automated software is a highly reproducible, practical, and faster method to analyze infrared meibography images with excellent correlation with the manual analysis.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Quantitative assessment of the effect of acute anaerobic exercise on macular perfusion via swept-source optical coherence tomography angiography in young football players
    (SPRINGER, 2019) Karakucuk, Yalcin; Okudan, Nilsel; Bozkurt, Banu; Belviranli, Muaz; Sezer, Tugba; Gorcuyeva, Sona
    Aim To evaluate the effect of acute anaerobic exercise on macular perfusion measured by swept-source optical coherence tomography angiography (SS-OCTA) in young football players. Materials and methods Football players with ages between 18 and 20 years were included into the study. After a detailed ophthalmological examination, physiological parameters including height (cm), body weight (kg), body fat percentage (%), systemic blood pressure (BP) (mmHg), hematocrit values (%), oxygen saturation pO(2) (%) and heart rate (bpm) were recorded. Intraocular pressure (IOP) (mmHg) and SS-OCTA using DRI OCT Triton (Topcon, Tokyo, Japan) were measured immediately before and after Wingate test. Results Out of 20, 16 participants completed the study. All participants were males with a mean age of 18.12 +/- .34 years. Systolic BP, hematocrit and heart rate increased, while pO(2) and IOP decreased remarkably after Wingate test (p < .01). After anaerobic exercise, there was an increase in mean FAZ area in superficial capillary plexus (FAZs) which was not significant (p = .13), while decrease in FAZ area in deep capillary plexus (FAZd) (mm(2)) was remarkable (p = .04). No changes were observed in mean vessel density (VD) (%) in superficial capillary plexus (VDs), deep capillary plexus (VDd), choriocapillaris (VDcc), central macular thickness (CMT) (mu m) and subfoveal choroidal thickness (SFCT) (mu m) after Wingate test (p > .05). FAZd and some of the VD parameters showed a significant correlation with BP (p < .05). Conclusion Acute anaerobic exercise seems not to alter either mean VD in retina and choroid or CMT and SFCT. Among OCTA parameters, only FAZd decreased remarkably.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim