Assessment of Plug Angle Effect on Exergy Efficiency of Counterflow Ranque-Hilsch Vortex Tubes With the Exergy Analysis Method
Küçük Resim Yok
Tarih
2009
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Gazi Universitesi Muhendislik-Mimarlik
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study, the experimental data was gathered from Ranque-Hilsch vortex tube with 5 air nozzles, an inner-diameter of 9 mm and with 12 diameter to length ratio, with 30°, 60°, 90°, 120°,150° conic 5 mm diameter plug tip angles. The experimental system was modelled as a thermo-dynamic öpen system. ??inlet, ??outlet, İ, and the exergy efficiency of RHVT were calculated and the exergy band diagram of RHVT was also presented. It was also found out that the exergy efficiency was low for low levels of Pinlet and it was found to be high with higher levels of Pinlet- At the end of the calculations, it was determined that the exergy efficiency of the system, changed between 1,14 and 40,21 and it was determined that the exergy efficiency was high for ?=90°.
Açıklama
Anahtar Kelimeler
Energy use, Exergy analysis, Ranque-Hilsch vortex tube
Kaynak
Journal of the Faculty of Engineering and Architecture of Gazi University
WoS Q Değeri
Scopus Q Değeri
Q2
Cilt
24
Sayı
3
Künye
Dinçer, K., Başkaya, S., (2009). Assessment of Plug Angle Effect on Exergy Efficiency of Counterflow Ranque-Hilsch Vortex Tubes With the Exergy Analysis Method. Journal of the Faculty of Engineering and Architecture of Gazi University, 24(3), 533-538.