Lanthony renk testinin güvenilirliği

dc.contributor.authorAcaroğlu, Şerife
dc.contributor.authorKemal, Gündüz
dc.contributor.authorZengin, Nazmi
dc.contributor.authorOkudan, Süleyman
dc.contributor.authorOkka, Mehmet
dc.contributor.authorÖzbayrak, Nilgün
dc.date.accessioned2020-03-26T16:24:42Z
dc.date.available2020-03-26T16:24:42Z
dc.date.issued1996
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractBu çalışmada tashihli görmeleri Snellen eşelinde 0.8 ve üzerinde olan, tespit edilebilir retina patolojisi olmayan, anamnezde ailesinde ve kendisinde renk görme defekti olmadığı belirlenen 184 olguya Lanthony yeni renk testi uygulandı. Olguların en küçüğü 7, en büyüğü 65 yaşında olup, 97 olgu kadın, 87 olgu İse erkekti. Tüm olgulara test monoküler olarak standart şartlarda uygulandı. Olguların hataları standart ayınm ve renk sınıflandırması grafiklerinde incelenerek yaş grupları, cinsiyet, doymuşluk seviyelerine ve hatalı piyon adlarına göre değerlendirildi. Hiçbir olguda seperasyon aşamasında patolojik hata skoruna rastlanmadı. Renk sınıflandırması aşamasında ise hiçbir olguda belirli bir renk defekti aksına uygunluk tespit edilmedi ve hatalar non-spesifik olarak kabul edildi. Pratikte kulandan diğer renk testlerinde olduğu gibi bu yöntemin de başarısının sınırlı olduğu ve tek başına tam olarak güvenilir olmadığı anlaşıldı.en_US
dc.description.abstractIn this study, Lanthony' s new color test was applied to 184 subjects with corrected visual acuities of 0.8 or better in Snellen chart with no detectable retinal pathology, and color vision defects in the past history. The youngest subject was 7 and the oldest one was 65 years old. 97 of the subjects were women and 87 were men. The test was applied as monocularly on all subjects under standard conditions. The errors made were examined in saturation and co¬lor classification graphs, and were evaluated according to the age groups, sexuality, seperation levels and the names of wrong disks. During seperation stage, no pathologic score was seen in any of the cases. During the color classification stage, no appropriateness to a specific color defect axis was seen in any of the cases and all the errors were considered to be non-specific. It was concluded that like other color tests that are been currently used in practice, the success of this method was limited, and it was not trustworthy by itself.en_US
dc.identifier.endpage162en_US
dc.identifier.issn1300-4786en_US
dc.identifier.issue2en_US
dc.identifier.startpage155en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TkRFME5UUTA=
dc.identifier.urihttps://hdl.handle.net/20.500.12395/16358
dc.identifier.volume3en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofMN Oftalmolojien_US
dc.relation.publicationcategoryDiğeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectGöz Hastalıklarıen_US
dc.titleLanthony renk testinin güvenilirliğien_US
dc.title.alternativeThe reliability of lanthony's color testen_US
dc.typeOtheren_US

Dosyalar