İlerletme genioplastisinde kullanılan 5 farklı fiksasyon sisteminin stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesi

dc.authorid0000-0002-3447-0065en_US
dc.authorid0000-0001-5060-8901en_US
dc.contributor.authorAktı, Ahmet
dc.contributor.authorKalaycı, Abdullah
dc.date.accessioned2023-01-16T13:28:14Z
dc.date.available2023-01-16T13:28:14Z
dc.date.issued2020en_US
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAmaç: Bu genioplasti çalışmasının amacı; segmentlerinin fiksasyonunda kullanılan titanyum monokortikal miniplak ve bikortikal vida sistemlerinin deplasman miktarı, kemikte oluşturduğu asal stresler ile plak ve vidalarda oluşan von-mises stres dağılımlarının sonlu elemanlar analizi ile karşılaştırılmasıdır. Gereç ve Yöntemler: Çalışmamızda alt çene ucunda genioplasti osteotomisi yapılarak distal fragman anteriora doğru 5 mm ilerletilmiştir. Fiksasyon olarak tek genioplasti plağı, 2 adet düz plak, 3 adet düz plak, 2 adet bikortikal vida ve 3 adet bikortikal vida fiksasyon modellerinin kullanıldığı 5 farklı modelde, alt segmente linguale doğru horizontal yönde 80 N’ luk kuvvet uygulanarak ortaya çıkan deplasman ve stres değerleri sonlu elemanlar analizi ile değerlendirilmiştir. Bulgular: En az deplasman üç adet titanyum bikortikal vida ile yapılan fiksasyon modelinde izlenirken, en fazla deplasman tek genioplasti plağı fiksasyon modelinde izlenmiştir. Materyallerde en az von-mises stres üç adet titanyum bikortikal vida ile yapılan fiksasyon modelinde, en fazla von-mises stres tek genioplasti plağı fiksasyon modelinde izlenmiştir. Kemikte en fazla gerilme stresi (Pmax) üç adet düz plak fiksasyon modelinde izlenirken en az gerilme stresi plak kullanılan fiksasyon modellerinde izlenmiştir. Kemikte en fazla sıkışma stresi (Pmin) iki adet bikortikal vida fiksasyon modelinde izlenirken en az sıkışma stresi iki ve üç adet düz plak fiksasyon modellerinde izlenmiştir. Sonuç: Bikortikal vida grupları, deplasman ve von-mises gerilme stresleri açısından daha iyi sonuç vermekle birlikte, plak grupları gerilme ve sıkışma stresleri açısından daha elverişli bulunmuştur. Tüm bunlarla birlikte sonuçlar tüm gruplar için fizyolojik sınırlar içerisindedir.en_US
dc.description.abstractBackground: The aim of this genioplasty study is the comparison of titanium monocortical miniplate and bicortical screw fixation systems in terms of displacement, primary stresses and von-mises stress by finite element analysis. Methods: In our study, genioplasty osteotomy was performed and the fragment was placed 5 mm anterior. In 5 different models using single genioplasty plate, 2 flat plates, 3 flat plates, 2 bicortical screws and 3 bicortical screw fixation models as fixation, 80 N force was applied to the distal segment in the horizontal direction. The displacement and stress values were evaluated by finite element analysis. Results: The shortest displacement was observed in the three titanium bicortical screws system, while the longest displacement was observed in the single genioplasty plate system. The lowest and highest von-mises stress was seen in three titanium bicortical screw system and single genioplasty plate, respectively. The maximum von-mises stress was observed in three flat plate fixation system, while the minimum von-mises was observed in plate fixation system. The maximum compression bone stress was recorded in two bicortical screw system, the minimum compression bone stress was recorded in two and three flat plate systems. Conclusion: Although bicortical screw groups give better results in terms of displacement and von-mises stress stresses, plate groups were found more favorable in terms of stress and compression stresses. However, the results are within physiological limits for all groups.en_US
dc.identifier.citationKalaycı, A., Aktı, A., (2020). İlerletme genioplastisinde kullanılan 5 farklı fiksasyon sisteminin stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesi. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 7 (3), 364-372. Doi: 10.15311/selcukdentj.735291en_US
dc.identifier.doi10.15311/selcukdentj.735291en_US
dc.identifier.endpage372en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue3en_US
dc.identifier.startpage364en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/44804
dc.identifier.volume7en_US
dc.institutionauthorAktı, Ahmet
dc.institutionauthorKalaycı, Abdullah
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectFiksasyonen_US
dc.subjectgenioplastien_US
dc.subjectsonlu eleman analizien_US
dc.subjectFixationen_US
dc.subjectgenioplastyen_US
dc.subjectfinite element analysisen_US
dc.titleİlerletme genioplastisinde kullanılan 5 farklı fiksasyon sisteminin stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesien_US
dc.title.alternativeEvaluation of stability and stress distributions of 5 different fixation systems used in advancement genioplasty by finite element analysisen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7-3-1.pdf
Boyut:
959.43 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: