Spontan Tepe Akım Hızları Weaning Belirteci Midir?

dc.contributor.authorBahar, İlhan
dc.contributor.authorBaldane, Süleyman
dc.contributor.authorElay, Gülseren
dc.contributor.authorCoşkun, Ramazan
dc.contributor.authorGündoğan, Kürşat
dc.contributor.authorGüven, Muhammet
dc.contributor.authorSungur, Murat
dc.date.accessioned2020-03-26T18:59:27Z
dc.date.available2020-03-26T18:59:27Z
dc.date.issued2015
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractAmaç: Mekanik ventilatörden ayırmada kullanılan birçok parametre mevcuttur. Ancak bu parametrelerin sonucu tahmin etme başarısı sınırlıdır. Bu çalışmadaki amacımız spontan solunum denemeleri (SBT) sırasında, spontan ekspiratuar (SPEF) ve spontan inspiratuar (SPİF) tepe akım hızlarının weaning başarısını tahminde etkisini ölçmekti.Gereç ve Yöntemler: Çalışmaya, Mart 2011 ile Mayıs 2012 yılları arasında Erciyes Üniversitesi Tıp Fakültesi Genel Cerrahi ve Dahili Yoğun bakımlarında en az 24 saat mekanik ventilatör (MV) tedavisi alan hastalar alındı. Spontan soluyan hastalar 30 dakika boyunca T parçası aracığıyla spontan solunum çalışması (SBT)'na alındı ve SPIF ve SPEF değerleri ölçüldü. Hastalar 30 dakika boyunca SBT'yi tolere ettiyse ekstübe edildiler. Hastalar ekstübasyondan sonra 48 saat içinde tekrar entübe olmaları durumunda başarısız weaning olarak değerlendirildi.Bulgular: Çalışma 36 hasta ile tamamlandı, 11 hasta başarısız oldu, 25 hasta başarılı oldu. Her iki grupta da eğri altında kalan alan (AUC),SBT sırasında ölçülen dakikalık SPEF ve SPEF değerleri dakikalık ROC analizi ile hesaplandı. Maksimum AUC değeri 23. dakikada SPIF için (0,564; %95 CI: 0,363-0,764) ve 9. dakika SPEF değeri . SPIF için 23. dakikada kesim değeri 26,7 litre/dakika, hesaplanan sensitivite ve spesifite değerleri sırasıyla %72 ve %42 olarak bulundu. SPEF için 9. dakika kesim değeri 24,7 litre/dakika, sırasıyla sensitivite ve spesifite değerleri %63,6 ve %48 olarak bulundu. Sonuç: Biz çalışmamızda geleneksel weaning prediktörleriyle karşılaştırdığımızda ,dakikalık SPIF ölçümlerinin en iyi spesifiteye, dakikalık SPEF ölçümlerinin de en iyi sensitiviteye sahip olduğunu belirledik Bu konuda daha geniş çalışmalara ihtiyaç vardır.en_US
dc.description.abstractObjective: Numerous parameters have been suggested for the prediction of weaning from mechanical ventilation; however, these parameters have limited success in the prediction of weaning outcome. This study aims to assess the success of peak flow rates [spontaneous peak inspiratory flow rate (SPIF) and spontaneous peak expiratory flow rate (SPEF)] that were measured during a spontaneous breathing trial (SBT) for the prediction of weaning outcome. Material and Methods: Patients who were managed and who received mechanical ventilation support for at least 24 h in the Internal Medicine and General Surgery Intensive Care Units of Erciyes University, School of Medicine between March, 2011 and May, 2012 were included in this study. Over 30 min, SPIF and SPEF values were measured during SBT in patients who were spontaneously breathing through a T-tube. Patients who tolerated the 30-min SBT were extubated. Patients who did not require reintubation for 48 h after extubation were considered as successful weaning, whereas those who required re-intubation were considered as weaning failure. Results: The study was completed with a total of 36 patients with 11 patients in the failure group and 25 in the success group. In both the groups, the area under curve (AUC) was calculated for each minute via ROC analysis using minute SPIF and SPEF values that were measured during SBT. The maximum AUC was calculated at 23 min for SPIF (0.564; 95% CI: 0.363-0.764) and at 9 min for SPEF (0.542; 95% CI: 0.316-0.3769). When the cut-off value for SPIF was accepted as >26.7 l/min at 23 min, sensitivity and specificity were calculated as 72.0% and 48.0%, respectively. When the cut-off value for SPEF was accepted as >24.7 l/min at 9 min, sensitivity and specificity were calculated as 63.6% and 48.0%, respectively. Conclusion: We believe that minute SPIF measurement, which has better sensitivity, and minute SPEF measurement, which has better specificity, compared with the available traditional predictors may be used as potential bedside weaning predictors when evaluated in comprehensive studies.en_US
dc.identifier.endpage43en_US
dc.identifier.issn1309-6222en_US
dc.identifier.issue2en_US
dc.identifier.startpage39en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRrNU56STJOZz09
dc.identifier.urihttps://hdl.handle.net/20.500.12395/31527
dc.identifier.volume6en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofDahili ve Cerrahi Bilimler Yoğun Bakım Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectCerrahien_US
dc.titleSpontan Tepe Akım Hızları Weaning Belirteci Midir?en_US
dc.title.alternativeAre Spontaneous Peak Flow Rates Predictors of Weaning?en_US
dc.typeArticleen_US

Dosyalar