The effect of embedding length and concrete cover thickness on bond strength in basalt aggregate concrete

dc.contributor.authorGörhan, Gökhan
dc.contributor.authorKürklü, Gökhan
dc.date.accessioned2018-06-01T10:05:31Z
dc.date.available2018-06-01T10:05:31Z
dc.date.issued2017
dc.descriptionURL: http://sutod.selcuk.edu.tr/sutod/article/view/400en_US
dc.description.abstractThis study investigated the effect of concrete cover thickness and embedding length on bond strength in concretes depending on the bonding properties of basalt aggregate in cement matrix. B420C construction steel with a diameter of 12 mm was centrally embedded in concrete samples for bond tests. CEM I 42.5 R cement and basalt aggregate were used for the production of concrete samples. 'Lollipop’-shaped reinforced concrete samples were prepared to make sure that concrete cover thickness is equal in the reinforcement circumference for the bond tests. These samples were prepared in nine different sizes with three different diameters and at three different height/diameter ratios. The results show that embedding depths of reinforcements in the samples with a diameter of 50 mm have no significant effect on bond strength. It has, therefore, been determined that the cylinder diameter of the concrete should be greater than 50 mm.en_US
dc.description.abstractBu çalışmada çimento matrisi içerisinde bazalt agregasının yapışma özelliğine bağlı olarak aderans dayanımına beton örtü kalınlığının ve kenetlenme boyunun etkisi araştırılmıştır. Aderans deneyleri için beton örneklerine 12 mm çapında B420C tipi inşaat çeliği merkezi olarak gömülmüştür. Beton örneklerin üretimi için CEM I 42.5 R tipi çimento ve bazalt agregası kullanılmıştır. Aderans testlerinde beton örtü kalınlığının betonarme ortamda eşit olması için Lolipop şekilli beton örnekleri hazırlanmıştır. Bu örneklerde; üç farklı çapta ve üç farklı narinlik (boy/çap) oranlarında olmak üzere dokuz farklı boyutta hazırlanmıştır. Sonuç olarak 50 mm çaplı örneklerde donatıların gömülme derinliklerinin aderans gerilmelerinde kayda değer bir değişikliğe neden olmamalarından ötürü beton silindir çapının 50 mm üzerinde olması gerektiği belirlenmiştir.en_US
dc.identifier.citationGörhan, G., Kürklü, G. (2017). The effect of embedding length and concrete cover thickness on bond strength in basalt aggregate concrete. Selçuk-Teknik Dergisi, 16, (3), 144-160.en_US
dc.identifier.endpage160
dc.identifier.issn1302-6178en_US
dc.identifier.startpage144
dc.identifier.urihttps://hdl.handle.net/20.500.12395/10930
dc.identifier.volume16
dc.language.isoenen_US
dc.publisherSelçuk Üniversitesi Teknik Bilimler Meslek Yüksekokuluen_US
dc.relation.ispartofSelçuk-Teknik Dergisien_US
dc.relation.publicationcategoryMakale - Kategori Belirleneceken_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectBonden_US
dc.subjectPull-outen_US
dc.subjectConcrete cover thicknessen_US
dc.subjectEmbedding lengthen_US
dc.subjectAderansen_US
dc.subjectBeton örtü kalınlığıen_US
dc.subjectKenetlenme boyuen_US
dc.titleThe effect of embedding length and concrete cover thickness on bond strength in basalt aggregate concreteen_US
dc.title.alternativeBazalt agregalı betonda kenetlenme boyunun ve beton örtü kalınlığının aderans gerilmesine etkisien_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Gökhan GÖRHAN Gökhan KÜRKLÜ.pdf
Boyut:
449.22 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.51 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: