Trakeal Entübasyonda Oluşan Hemodinamik Yanıtın Kontrolünde Sufentanilin Farklı Dozlarının Karşılaştırılması

dc.contributor.authorTuncer, Sema
dc.contributor.authorReisli, Ruhiye
dc.contributor.authorYosunkaya, Alper
dc.contributor.authorTavlan, Aybars
dc.contributor.authorUzun, Süleyman
dc.contributor.authorÖkeşli, Selmin
dc.date.accessioned2020-03-26T16:45:16Z
dc.date.available2020-03-26T16:45:16Z
dc.date.issued2003
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractÇalışmamızda laringoskopi ve entübasyona hemodinamik yanıtta sufentanilin en uygun, yeterli ve güvenilir dozunu belirlemeyi amaçladık. Çalışma elektif cerrahi planlanan ASA I-II sınıfı, kardiyovasküler hastalığı olmayan, normotansif 45 olguda gerçekleştirildi. Olgular rasgele olarak 3 eşit gruba ayrıldı. Bütün olgulara intravenöz 0.03 mg kg-1 midazolam premedikasyonundan 10 dk sonra, Grup I'e (GI) 0.1 µg kg-1, Grup II'ye (GII) 0.15 µg kg-1, Grup III'e (GIII) 0.2 µg kg-1 sufentanil intravenöz uygulandı. Yaklaşık 2 dk sonra 2 mg kg-1 propofol ve 1.5 mg kg-1 süksinil kolin verildi. Olgular direk laringoskopi ile entübe edildiler. Sistolik arter basıncı (SAB), diyastolik arter basıncı (DAB), ortalama arter basıncı (OAB) ve kalp atım hızı (KAH), başlangıçta (midazolam uygulamasından 10 dk sonra) (t0), propofol uygulamasından önce (t1), laringoskopi öncesi (t2), trakeal entübasyondan sonra 1. ve 3 dk (t3, t4) ölçüldü. Grup içi parametre değerleri karşılaştırıldığında G I'de entübasyon sonrası (t3, t4) KAH'da artış gözlendi (p0.05). G II'de indüksiyon sonrası (t2) SAB değeri başlangıç değeri ile karşılaştırıldığında anlamlı olarak düşük bulundu (p0.05). G III'de tüm hemodinamik parametre değerleri (SAB, DAB, OAB; KAH) t2, t3 ve t4' de anlamlı düşük bulundu (p0.05). Gruplar karşılaştırıldığında ise G I ve G II arasında hemodinamik parametre değerleri açısından tüm ölçüm zamanlarında farklılık gözlenmezken,G III'de G I'e göre t3'de SAB, OAB ve KAH; t4'de SAB, DAB, OAB ve KAH'da, G II'ye göre, t3 ve t4'de KAH değerleri anlamlı olarak düşük bulundu (p0.05). GIII'de 7 olguda bradikardi gözlendi. Sonuç olarak, kardiovasküler hastalığı olmayan, normotansif olgularda laringoskopi ve entübasyon sonrası cevabın önlenmesinde 0.15 µg kg-1 sufentanilin yeterli ve güvenilir olduğu kanısındayız.en_US
dc.description.abstractIn our study, we aimed to determine the most appropriate, sufficient, and safe dose of sufentanil in the hemodynamic response to laringoscopy and intubation. This study was performed on 45 ASA I-II physical status, without cardiovascular illness, normotansive patients planned for elective surgery. Patients were randomized into three equal groups. All patients received an intravenous midazolam premedication (0.03 mg kg-1). Ten minutes after, 0,1 µg kg-1 sufentanil in Group I (GI), 0.15 µg kg-1 sufentanil in Group II (GII) and 0.2 µg kg-1 sufentanil in Group III (GIII) were administrated intravenously. About two minutes after, all patients received 2 mg kg-1 propofol and 1.5 mg kg-1 succinylcholine. The patients were intubated under direct laringoscopy. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP) and heat rate (HR) were measured: at the beginning (10 min. after midazolam application) (t0), before propofol (t1), before laryngoscopy (t2), 1 and 3 minutes after the tracheal intubation (t3,t4). When the group parameter values were evaluated, it was observed that there was an significant increase in HR after the intubation (t3,t4) in G I (p>0.05). In G II SAP was significantly decrease after induction (t2) when compared with t0 (p<0.05). All hemodynamic parameter values (SAP, DAP, MAP, HR) were found significantly decrease at t2, t3, t4 in G III (p<0.05). When the groups were compared, there were no differences in all measurement times in the aspect of hemodynamic parameter values between G 1 and G II (p>0.05). SAP, MAP, HR values at t3 and SAP, DAP, MAP, HR at t4 were found significantly lower in G III than in G I (p<0.05) and HR values at t3, t4 were found significantly lower in G III than G II (p<0.05). Bradycardia occurred in seven patients in G III. As a result; We think that 0.15 µg kg-1 sufentanil was safe and satisfactory to suppress the response after laryngoscopy and tracheal intubation in healthy normotensive patients without cardiovascular disease.en_US
dc.identifier.citationTuncer, S., Reisli, R., Yosunkaya, A., Tavlan, A., Uzun, S., Ökeşli, S., (2003). Trakeal Entübasyonda Oluşan Hemodinamik Yanıtın Kontrolünde Sufentanilin Farklı Dozlarının Karşılaştırılması. Türk Pediatri Arşivi, 31(3), 116-120.
dc.identifier.endpage120en_US
dc.identifier.issn1306-0015en_US
dc.identifier.issn1308-6278en_US
dc.identifier.issue3en_US
dc.identifier.startpage116en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TWpJek16TXo=
dc.identifier.urihttps://hdl.handle.net/20.500.12395/18302
dc.identifier.volume31en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorTuncer, Sema
dc.institutionauthorReisli, Ruhiye
dc.institutionauthorYosunkaya, Alper
dc.institutionauthorTavlan, Aybars
dc.institutionauthorUzun, Süleyman
dc.institutionauthorÖkeşli, Selmin
dc.language.isotren_US
dc.relation.ispartofTürk Pediatri Arşivien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectAcil Tıpen_US
dc.subjectAnestezien_US
dc.titleTrakeal Entübasyonda Oluşan Hemodinamik Yanıtın Kontrolünde Sufentanilin Farklı Dozlarının Karşılaştırılmasıen_US
dc.title.alternativeComparison of Different Doses of Sufentanil for Control of Hemodynamic Response to Tracheal Intubationen_US
dc.typeArticleen_US

Dosyalar