Reduced transport numbers of PolysulfoneMembranes from the initial time EMF measurements

Küçük Resim Yok

Tarih

2012

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Initial membrane potentials of polysulfone cation exchange membranes were measured with KCl, NaCl, LiCl CaCl 2 and FeCl 3 solutions by using Ag/AgCl electrodes. The measurements were carried out for KCl / unsupported polysulfone cation exchange membranes (SA 3S) or polyester supported polysulfone cation exchange membranes (SA 3T) / KCl, NaCI, LiCI, CaCl 2 and FeCl 3 systems. The concentration of KCl, C 1, was kept constant at 1.10 -2 M in one cell; however the concentrations of KCl, NaCI, LiCl, CaCl 2 and FeCl 3, C 2, in the other cell were changed from 1.10 -4 M to 2.0 M. The Supported face of SA 3T membrane was brought to equilubrium with the left- hand solution and then, the unsupported face of SA 3T membrane was exposed to the right-hand solution. Transport number of K +, Na +, Li +, Ca +2, Fe +3 ions corresponding to the each of two surface layers of the membrane was evaluated from the initial time and the fifth minute emf measurements. The results were compared with between unsupported polysulfone cation exchange membranes and polyester supported polysulfone cation exchange membranes.

Açıklama

Anahtar Kelimeler

? mean, Cation exchange membrane, Initial time, The mean reduced transport number

Kaynak

Gazi University Journal of Science

WoS Q Değeri

Scopus Q Değeri

Q3

Cilt

25

Sayı

3

Künye