Ön kamara bulanıklığının gün içi değişimi

dc.contributor.authorAdam, Mehmet
dc.contributor.authorOkka, Mehmet
dc.contributor.authorKerimoğlu, Hürkan
dc.contributor.authorPekel, Hürriyet
dc.contributor.authorTurgut, Banu Öztürk
dc.contributor.authorBozkurt, Banu
dc.contributor.authorOkudan, Süleyman
dc.date.accessioned2020-03-26T19:00:01Z
dc.date.available2020-03-26T19:00:01Z
dc.date.issued2015
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractAmaç: Laser flaremetre cihazı ile yapılan ön kamara bulanıklık ölçümlerin ideal zamanı ve tekrarlanabilirliğinin araştırılması. Gereç ve Yöntem: Kırk beş gönüllünün sabah saat 8.00da laser flaremetre cihazı ile ön kamara bulanıklık ölçümleri yapılmış ve bu ölçümler aynı gün saat 12.00 ve saat 16.00da tekrarlanmıştır. Bulgular: Gönüllülerin 25i (%55,5) kadın ve 20si (%44,5) erkekti ve ortalama yaşları 28,677,40 yıldı. Olguların oftalmolojik muayenelerini takiben alınan ortalama ön kamara bulanıklık ölçümleri sabah saat 8:00da 5,941,41 foton/msn, saat 12de 5,651,45 foton/msn, saat 16.00da 5,791,20 foton/msn idi. Ölçümler arasında anlamlı bir farklılık saptanmadı (p0,08). Katılımcıların göz rengine göre yapılan alt grup analizinde de kahverengi, ela ve yeşil göz renkler arasında anlamlı bir farklılık bulunmamıştır (p0,21). Korelasyon analizinde gün içinde alınan üç ölçümün de yaşla korele olduğu görülmüştür (r0,24, p0,03; r0,41, p0,01, r0,27 p0,01). Sonuç: Ön kamara bulanıklık ölçümlerinde sağlıklı bireylerde gün içerisinde anlamlı bir değişiklik saptanmamıştır ancak yaşla pozitif korelasyon göstermektedir. Bu nedenle gün içindeki tüm ölçümler güvenilirdir ve tekrarlanabilirliği yüksektir. (Turk J Ophthalmol 2015; 45: 52-5)en_US
dc.description.abstractObjectives: To investigate the ideal time and reproducibility of anterior chamber flare measurements. Ma­te­ri­als and Met­hods: Anterior chamber flare measurements were performed with laser flaremetre device at 8 am to 45 volunteers and these measurements were repeated on the same day at 12 pm and 4 pm. Re­sults: Twenty-five (55.5%) of the volunteers were women and 20 (44.5%) were men; mean age was 28.67±7.40 (18-49) years. The mean anterior chamber flare measurements taken following the ophthalmologic examination were 5.94±1.41 foton/msn at 8 am, 5.65±1.45 foton/msn at 12 pm, and 5.79±1.20 foton/msn at 4 pm. No statistical difference was found between the measurements (p0.08). Subgroup analysis according to eye color, revealed no significant difference between flare measurements in brown, hazel, and green eyes (p0.21). Correlation analysis demonstrated association between age and all flare measurements within the day (r0.24, p0.03; r0.41, p0.01, r0.27, p0.01). Conclusion: No significant diurnal change was detected in the flare measurements of our study subjects but positive correlation with age was observed. Hence, all flare measurements within a day are reliable and have high repeatability in healthy subjects. (Turk J Ophthalmol 2015; 45: 52-5)en_US
dc.identifier.endpage55en_US
dc.identifier.issn1300-0659en_US
dc.identifier.issn2147-2661en_US
dc.identifier.issue2en_US
dc.identifier.startpage52en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRjd056YzJOZz09
dc.identifier.urihttps://hdl.handle.net/20.500.12395/31677
dc.identifier.volume45en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofTürk Oftalmoloji Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectGöz Hastalıklarıen_US
dc.titleÖn kamara bulanıklığının gün içi değişimien_US
dc.title.alternativeDiurnal variation of anterior chamber flareen_US
dc.typeArticleen_US

Dosyalar