Evaluating the Parameters for Electrode Wear Rate in Electrical Discharge Machining of H13 Steel

Yükleniyor...
Küçük Resim

Tarih

2023 Nisan

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Selçuk Üniversitesi

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

In this study, H13 steel, which is widely used in mold making, was processed by the electroerosion method. A copper electrode with a diameter of 12 mm was used in the experiments. Taguchi L18 experiment list was created by using 3 different cutting parameters. At the end of the experiments, electrode wear rates (EWR) were found by controlling the initial and final weights of the electrode. Ampere (A) was the most effective parameter for electrode wear. According to the analysis of variance (ANOVA) results, Amper's contribution rate was 63.99%. At the end of the study, Regression analysis was performed, and a mathematical model was developed for the electrode wear rate.

Açıklama

Anahtar Kelimeler

ANOVA, Electro-erosion, EWR, H13 Steel, Taguchi

Kaynak

Selcuk University Journal of Engineering Sciences

WoS Q Değeri

Scopus Q Değeri

Cilt

22

Sayı

1

Künye

Yaka, H., Malo, Y., (2023). Evaluating the Parameters for Electrode Wear Rate in Electrical Discharge Machining of H13 Steel. Selcuk University Journal of Engineering Sciences, 22(1), 33-37.