Efficiency of silver coated urinary catheter in catheter-associated urinary tract infection in critical care unit
dc.contributor.author | Teke T. | |
dc.contributor.author | Yavuz Z. | |
dc.contributor.author | Atalay H. | |
dc.contributor.author | Maden E. | |
dc.contributor.author | Solak Y. | |
dc.contributor.author | Uzun K. | |
dc.date.accessioned | 2020-03-26T18:05:41Z | |
dc.date.available | 2020-03-26T18:05:41Z | |
dc.date.issued | 2010 | |
dc.department | Selçuk Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Aim: Urinary tract infection (UTI) is the most prevalent cause of nosocomial infections, with an incidence of 40%. The incidence of urosepsis occurs in approximately 16% of the ICU patient populations. The purpose of this study was to determine the efficacy of a silver coated urinary catheter in prevention of catheter-associated UTI. Material and Methods: We investigated 21 patients (mean age with 71.4±9.0 year and 14 M, 7 F) foley silicon urinary catheter and 20 patients (mean age with 67.6±8.7 year and 15 M, 5 F) with silver coated urinary catheter. In all patients, foley urinary catheters were changed with silver coated catheter in critical care unit. Results: The most common cause of infection was Klebsiella (33%). The susceptibility of gram negative microorganisms against antimicrobial agents were amicacin, piperacillin-tazobactam and carbapenem. The cost of antibiotic was higher in foley catheter group than silver coated group (p<0.001). Conclusion: Silver coated urinary catheter is expensive, it is cost effect according to urinary infection and antibiotic cost. | en_US |
dc.identifier.citation | Teke, T., Yavuz, Z., Atalay, H., Maden, E., Solak, Y., Uzun, K. (2010). Efficiency of Silver Coated Urinary Catheter in Catheter-Associated Urinary Tract İnfection in Critical Care Unit. Journal of Medical and Surgical Intensive Care Medicine, 1(2), 45-47. | |
dc.identifier.doi | 10.5152/dcbybd.2010.04 | en_US |
dc.identifier.endpage | 47 | en_US |
dc.identifier.issn | 1309-1689 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 45 | en_US |
dc.identifier.uri | https://dx.doi.org/10.5152/dcbybd.2010.04 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/25505 | |
dc.identifier.volume | 1 | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.institutionauthor | Teke T. | |
dc.institutionauthor | Yavuz Z. | |
dc.institutionauthor | Atalay H. | |
dc.institutionauthor | Maden E. | |
dc.institutionauthor | Solak Y. | |
dc.institutionauthor | Uzun K. | |
dc.language.iso | tr | en_US |
dc.publisher | AVES | en_US |
dc.relation.ispartof | Journal of Medical and Surgical Intensive Care Medicine | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Critical care | en_US |
dc.subject | Silver coated urinary catheter | en_US |
dc.subject | Urinary tract infection | en_US |
dc.title | Efficiency of silver coated urinary catheter in catheter-associated urinary tract infection in critical care unit | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Turgut TEKE.pdf
- Boyut:
- 50.81 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Full Text Access