İmplant dayanak bağlantı tiplerinin implant başarısına etkisinin retrospektif olarak değerlendirilmesi: Pilot çalışma

dc.authorid0000-0003-0414-0652en_US
dc.authorid0000-0003-3384-0092en_US
dc.authorid0000-0002-6102-9136en_US
dc.authorid0000-0003-0505-8685en_US
dc.contributor.authorUslu, Fatma
dc.contributor.authorEvlice, Burcu
dc.contributor.authorBenlidayı, M. Emre
dc.contributor.authorUçar, Yurdanur
dc.date.accessioned2023-01-16T12:59:47Z
dc.date.available2023-01-16T12:59:47Z
dc.date.issued2020en_US
dc.departmentBaşka Kurumen_US
dc.description.abstractAmaç: Bu çalışmanın amacı farklı implant dayanak bağlantı tiplerinin (konik ve uç uca birleşim) implant başarısına etkisini değerlendirmektir. Gereç ve Yöntemler: Kliniğimizde 2016 yılında implant üstü sabit protetik tedavisi tamamlanmış ve yükleme sonrası en az 1 yıllık kontrolleri yapılmış hastalar, dental implant tedavisi için risk oluşturabilecek parametreleri (yaş, medikal durum, meslek, cinsiyet, sigara kullanımı) değerlendirebilmek için çalışmaya dahil edildi. Klinik (sondlamada kanama, cep derinliği, plak indeksi, gingival indeks) ve radyografik (kemik kaybı miktarı) değerlendirmeler kaydedildi. Konik ve uç uca (butt-joint) birleşimi olan implantların başarısı karşılaştırıldı. Farklı implant sistemleri de implant başarısı açısından karşılaştırıldı. Veri analizinde t-testi, tek yönlü ANOVA ve Tukey testleri kullanıldı (?=0.05). Bulgular: Kliniğimizde kullanılan farklı dental implantlar (Implantium, Nucleoss, Bego, Astra EV, Biohorizons) ile tedavi edilen 19 hastada uygulanan 11 konik ve 8 uç uca birleşimli implant dayanak bağlantısının implant başarısına etkisi yüklemeden bir yıl sonra değerlendirildi. Sondlamada kanama, cep derinliği, plak indeksi, gingival indeks ve kemik kaybı miktarı açısından değerlendirildiğinde iki implant dayanak bağlantı tipi arasında istatiksel olarak anlamlı bir fark bulunamadı (p>0.05). İmplant sistemleri kendi aralarında ayrı ayrı değerlendirildiğinde kısa dönem implant başarısı açısından istatistiksel olarak anlamlı bir fark görülmedi (p>0.05). Sonuç: Bu retrospektif pilot çalışma çalışmanın sınırlamaları dahilinde implant dayanak bağlantısının kısa dönem implant başarısı üzerinde fark yaratmadığını gösterdi. İmplant dayanak bağlantı tipinin implantın uzun dönem başarısı üzerine etkisini daha büyük örneklem kullanılarak uzun dönem değerlendiren klinik araştırmalara ihtiyaç duyulmaktadır.en_US
dc.description.abstractBackground: The aim of this study was to analyze the effect of implant abutment connection on implant success. Methods: Patients who were rehabilitated in our clinic with implant supported fixed dental prosthesis in 2016 and followed up at least one year after loading were involved in the study. Risk parameters that might affect dental implant success were evaluated. Clinical (bleeding on probing, pocket probing depth, plaque index, gingival index) and radiographic evaluations (marginal bone loss) were recorded. Success of dental implants with conic and butt-joint connections were compared. Different dental implant brands were also evaluated. Data analysis was done using t-test, one-way ANOVA and Tukey tests (?=0.05). Results: Nineteen patients were rehabilitated with dental implants (Implantium, Nucleoss, Bego, Astra EV, Biohorizons). Eleven conic, eight butt-joint implant-abutment connections were evaluated after one year of loading. Implant abutment connection did not have a statistically significant effect on bleeding on probing, pocket depth, plaque index, gingival index and bone loss (p>0.05). No statistically significant difference was found on short-term implant success when different implant brands were compared (p>0.05). Further clinical studies are required to evaluate the effects of implant abutment connection type on the long-term success of implants. Conclusion: Within the limitations of this retrospective clinical study, results reveal that the design of the implant-abutment connection appears to have no significant impact on short-term implant success. Further clinical studies with much larger sample size are required to evaluate the effects of implant abutment connection type on the long-term success of implants.en_US
dc.identifier.citationUslu, F., Evlice, B., Benlidayı, M. E., Uçar, Y., (2020). İmplant dayanak bağlantı tiplerinin implant başarısına etkisinin retrospektif olarak değerlendirilmesi: Pilot çalışma. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 7 (1), 1-7. Doi: 10.15311/selcukdentj.492513en_US
dc.identifier.doi10.15311/selcukdentj.492513en_US
dc.identifier.endpage7en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/44781
dc.identifier.volume7en_US
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Başka Kurum Yazarıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectAlveoler kemik kaybıen_US
dc.subjectdiş implantıen_US
dc.subjectAlveolar bone lossen_US
dc.subjectdental implanten_US
dc.titleİmplant dayanak bağlantı tiplerinin implant başarısına etkisinin retrospektif olarak değerlendirilmesi: Pilot çalışmaen_US
dc.title.alternativeA retrospective study on effect of implant-abutment connection on implant success: A pilot studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7-1-1.pdf
Boyut:
651.78 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: