Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique

dc.contributor.authorDemir N.
dc.contributor.authorOzturk A.N.
dc.contributor.authorMalkoc M.A.
dc.date.accessioned2020-03-26T18:59:06Z
dc.date.available2020-03-26T18:59:06Z
dc.date.issued2014
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractObjective: To evaluate the marginal gap (MG) and absolute marginal discrepancy (MD) of full ceramic crowns with two finish line designs, shoulder and chamfer, using microcomputed tomography (micro-CT) before and after cementation. Materials and Methods: Sixty extracted human maxillary premolar teeth were divided into two groups based on the finish line design: Group I: 90° shoulder and Group II: 135° chamfer. The specimens were further grouped based on the type of full ceramic crown they received: Group A: Feldspathic Cerec inLab ceramic system, Group B: Cerec inLab aluminum oxide ceramic system and Group C: Lithium disilicate press ceramic system. Before cementation, five crowns from each group were scanned using micro-CT in two sections, sagittal and coronal, to determine the MG and MD values for four regions of the crown (sagittal buccal, sagittal lingual, coronal mesial and coronal distal). After cementation and thermal cycling, the scanning was repeated. Measurements were obtained from 10 points for each region, 80 points totally, to evaluate the MG and MD values. Files were processed using NRecon and CTAn software. Results were statistically analyzed using one- and two-way ANOVA and Tukey HSD tests (P = 0.05). Results: Full ceramic systems showed clinically acceptable marginal adaptation values. The Feldspathic Cerec inLab ceramic system generally presented the lowest variance, except in the MG values of the coronal mesial region. The MG and MD values of all ceramics increased significantly after cementation, except in the shoulder preparation design (sagittal buccal region) for MG and in the chamfer preparation design (sagittal lingual region) for MD values. Conclusions: Full-ceramic crowns showed clinically acceptable marginal adaptation values. The Feldspathic Cerec inLab ceramic system (Vitablocs Mark II) generally presented the lowest variance when compared with the other ceramics, except for the MG values on the mesial surface of the coronal section. © 2014 Dental Investigations Society.en_US
dc.identifier.doi10.4103/1305-7456.143612en_US
dc.identifier.endpage444en_US
dc.identifier.issn1305-7456en_US
dc.identifier.issue4en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage437en_US
dc.identifier.urihttps://dx.doi.org/10.4103/1305-7456.143612
dc.identifier.urihttps://hdl.handle.net/20.500.12395/31414
dc.identifier.volume8en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherDental Investigations Societyen_US
dc.relation.ispartofEuropean Journal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectFull ceramic crownsen_US
dc.subjectMarginal fiten_US
dc.subjectMicrocomputed tomography techniqueen_US
dc.titleEvaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) techniqueen_US
dc.typeArticleen_US

Dosyalar