Volatil Anesteziklerin Bakteri Üreme Hızına Etkileri

dc.contributor.authorTopal, Ahmet
dc.contributor.authorDuman, Ateş
dc.contributor.authorÖğün, Cemile
dc.contributor.authorŞahin, Tahir Kemal
dc.contributor.authorErol, Atilla
dc.contributor.authorArslan, Uğur
dc.contributor.authorÖkesli, Selmin
dc.date.accessioned2020-03-26T16:38:00Z
dc.date.available2020-03-26T16:38:00Z
dc.date.issued2002
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractAmaç: Anestezi cihazlarında kullanılan maske, konnektör, hortum ve nemli solunum devreleri, enfeksiyon ve kontaminasyon için iyi bir ortam sağlar. Ancak klinik uygulama sırasında kontaminasyon beklendiği kadar sık görülmemektedir. Volatil anesteziklerle anestezi verilen hastalarda postoperatif pulmoner enfeksiyon beklenenden daha az ortaya çıkmaktadır. Bu çalışmada volatil anesteziklerden halotan, izofluran ve sevofluranın P. aeruginosa, S. aureus ve E. coli'nin üreme hızı üzerine anestezi cihazı ortamında in vitro şartlarda etkilerini araştırmayı amaçladık. Yöntem: Buyyon içindeki P. aeruginosa, S. aureus ve E. coli'nin spektrofotometrede 450 n\mu dalga boyunda ışık kırıcılığı okunup bazal değer olarak kayıt edildi. Mikroorganizmalar anestezi cihazında % 50 oksijenli ortamda halotan, izofluran ve sevoflurana bir, iki, üç ve dört saat süreyle, 1 MAC ve 2 MAC'da üçer defa maruz bırakıldı. Sürelerin sonunda tekrar mikroorganizmaların ışık kırıcılığı okunup çıkış değeri olarak kayıt edildi. Aynı şekilde volatil anestezik verilmeden kontrol grubu çalışıldı. Bulgular: Halotan, izofluran ve sevofluran P. aeruginosa, S. aureus ve E. coli'nin üreme hızlarını bir, iki, üç ve dördüncü saatte inhibe etti. Inhibitör etki en fazla halotan, en az izofluran ile ortaya çıktı. Bu inhibitör etkiye en duyarlı mikroorganizmalar P. aeruginosa ve E. coli idi. S. aureus ise bu etkiye en dirençli mikroorganizma idi. Sonuç: In vitro şartlarda, halotan, izofluran ve sevofluran, P. aeruginosa, S. aureus ve E. coli'nin üreme hızlarını anestezi cihazı ortamında inhibe etmektedir.en_US
dc.description.abstractObjective: Anesthesia equipment such as masks, connectors, tubes and humid breathing circuits provide a good environment for infection and contamination. But contamination is not as frequent as expected during clinical practice. Postoperative pulmonary infections appear less than expected in patients anesthetized with volatile anesthetics. In this study, we aimed to study the in vitro effects of halothane, isoflurane and sevoflurane on the growth rate of P. aeruginosa, S. aureus and E. coli under anesthesia equipment conditions. Methods: The light absorbency of P. aeruginosa, S. aureus and E. coli was recorded as basic value at 450 n\mu with a spectrophotometer. Microorganisms inoculated in buyyon were subjected to one and two MAC halothane, isoflurane and sevoflurane for one, two, three and four hours in 50% oxygen within the anesthesia machine. The light absorbency of the microorganisms was recorded at the end of the exposure to volatile anesthetics. A control group was studied without volatile anesthetics. Results: Halothane, isoflurane and sevoflurane inhibited the growth rate of P. aeruginosa, S. aureus and E. coli at one, two, three and four hours. The inhibitory effect was greater with halothane and least with isoflurane, the growth rate was suppressed greater in P. aeruginosa and E. coli and least in S. aureus. Conclusion: Under in vitro conditions halothane, isoflurane and sevoflurane inhibit growth rate of P. aeruginosa, S. aureus and E. coli.en_US
dc.identifier.citationTopal, A., Duman, A., Öğün, C., Şahin, T. K., Erol, A., Arslan, U., Ökesli, S., (2002). Volatil Anesteziklerin Bakteri Üreme Hızına Etkileri. Genel Tıp Dergisi, 12(3), 95-100.
dc.identifier.endpage100en_US
dc.identifier.issn2602-3741en_US
dc.identifier.issue3en_US
dc.identifier.startpage95en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRjMk1EUTA=
dc.identifier.urihttps://hdl.handle.net/20.500.12395/17754
dc.identifier.volume12en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorTopal, Ahmet
dc.institutionauthorDuman, Ateş
dc.institutionauthorÖğün, Cemile
dc.institutionauthorŞahin, Tahir Kemal
dc.institutionauthorErol, Atilla
dc.institutionauthorArslan, Uğur
dc.institutionauthorÖkesli, Selmin
dc.language.isotren_US
dc.relation.ispartofGenel Tıp Dergisien_US
dc.relation.publicationcategoryDiğeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectGenel ve Dahili Tıpen_US
dc.subjectVolatil anestezikler
dc.subjectAntibakteriyel aktivite
dc.subjectNozokomiyal enfeksiyon
dc.subjectAnestezi cihazı
dc.subjectVolatile anesthetics
dc.subjectAntibacterial activity
dc.subjectNosocomial infection
dc.subjectAnesthesia equipment
dc.titleVolatil Anesteziklerin Bakteri Üreme Hızına Etkilerien_US
dc.title.alternativeThe Effects of Volatile Anesthetics to the Rate of Bacterial Growthen_US
dc.typeOtheren_US