Cam seramik CAD-CAM materyallerinde tekrarlanan fırınlama işleminin materyallerin mikrosertlik ve translusensisine olan etkisi

dc.authorid0009-0009-4733-8379
dc.contributor.advisorYöndem, İsa
dc.contributor.authorAkkese, İsa
dc.date.accessioned2024-11-01T11:14:49Z
dc.date.available2024-11-01T11:14:49Z
dc.date.issued2024
dc.departmentEnstitüler, Sağlık Bilimleri Enstitüsü, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractBu in vitro çalışmanın amacı; tekrarlanan fırınlama işleminin farklı bilgisayar destekli tasarım-bilgisayar destekli üretim (CAD-CAM) seramik materyallerin (Vita Suprinity, VITA Zahnfabrik BAD Sackingen, Almanya; IPS e.max CAD, Ivoclar Vivadent, Schaan, Lihtenşayn ve Amber Mill, Haas Corp., Güney Kore) translusensi (TP00) ve Vickers mikrosertlik değerine (VHN) etkisini incelemektir. CAD-CAM bloklardan 14x16x1,2 mm boyutlarında kesitler alınarak her materyalden 48 adet olmak üzere toplam 144 adet örnek elde edilmiştir. Örnekler tekrarlanan fırınlama sayısına göre (kontrol 1F, kristalizasyonu takiben glaze fırınlaması; 2F, kristalizasyonu takiben glaze fırınlaması ve 1 tekrarlanan fırınlama; 3F kristalizasyonu takiben glaze fırınlaması ve 2 tekrarlanan fırınlama; 5F kristalizasyonu takiben glaze fırınlaması ve 4 tekrarlanan fırınlama) dört gruba ayrılmıştır. Örneklerin Commission Internationale de I' Eclairage (CIE) L*, a* ve b* renk koordinatları bir spektrofotometre ile D65 standart aydınlatma kullanılarak ölçüldü. Grupların elde edilen TP00 ve VHN değerleri hesaplandı. Normal dağılıma uygunluk çarpıklık basıklık katsayıları ile incelenmiştir. Normal dağılım göstermeyen TP00 ve Vickers mikrosertlik değerlerinin analizinde iki yönlü ANOVA kullanılmıştır (p<0,05). TP00 değerleri materyal x fırınlama sayısı ikili etkileşimi arasında istatistiksel olarak bir fark gözlenmezken (p=0,445); materyal ve fırınlama sayısı istatistiksel olarak anlamlı bulunmuştur (p<0,05). Materyal gruplarının TP00 değerleri Amber Mill > IPS e.max CAD > Vita Suprinity. Fırınlama sayısına göre en yüksek TP00 değerini kontrol grupları göstermiştir. Materyal ve fırınlama sayısının etkisi Vickers mikrosertlik değerleri için istatistiksel olarak anlamlı iken (P<0,05), materyal x fırınlama sayısı etkileşimi istatistiksel olarak anlamlı bulunmamıştır (p=0,369). En yüksek VHN Amber Mill kontrol gruplarında gözlenmiştir. Tekrarlanan fırınlama işlemi CAD-CAM materyallerin translusensi ve mikrosertlik değerlerini etkilemektedir. Bu sebepten ötürü gereksiz fırınlama işlemi yapılmamalı ve fırınlama işlemi öncesi tüm ağız içi kontrollerin tamamlanması gerekmektedir.
dc.description.abstractThe aim of this in vitro study was to investigate the effect of repetitive firing on the translucency and Vickers microhardness of different computer-aided design-computer-aided manufacturing (CAD-CAM) ceramic materials (Vita Suprinity, VITA Zahnfabrik BAD Sackingen, Germany; IPS e.max CAD, Ivoclar Vivadent, Schaan, Lihtenşayn and Amber Mill, Haas Corp., Güney Kore). The CAD-CAM blocks were cut into 14x16x1.2 mm sections, and a total of 144 specimens, 48 of each material were obtained. These specimens were divided into four groups according to the numbers of firings (control 1F crystallization followed by repair firing, 2F (crystallization followed by 1 repair firings; 3F, crystallization followed by 2 repair firings and 5F, crystallization followed by 4 repair firings). The Commission Internationale de I' Eclairage (CIE) L*, a*, and b* color coordinates of the specimens were measured using a spectrophotometer and D65 standard illumination. The obtained TP00 and VHN values of the groups were calculated. Two-way ANOVA was used for the analysis of TP00 and Vickers values that did not show normal distribution (p<0,05). While there was no statistical difference between the material x number of firings interaction for the TP00 values (p=0,0445); the material type and number of firings were found to be statistically significant (p<0,05). The TP00 values of the material groups were Amber Mill > IPS e.max CAD > Vita Suprinity. According to the number of firings control groups showed the highest TP values. While the effect of material and number of firings was statistically significant for Vickers microhardness (P<0,05), the interaction between material x number of firings was not significant (p=0,369). The highest VHN was found Amber Mill control groups. The repetitive firings can affect the translucency and microhardness of CAD-CAM materials. For this reason, unnecessary firing process should not be performed and all intraoral controls should be completed before final firing.
dc.description.sponsorshipBu araştırma Selçuk Üniversitesi Bilimsel Araştırma Projeleri Koordinatörlüğü tarafından 21212030 proje numarası ile desteklenmiştir.
dc.identifier.citationAkkese, R. (2024). Cam seramik CAD-CAM materyallerinde tekrarlanan fırınlama işleminin materyallerin mikrosertlik ve translusensisine olan etkisi. (Doktora Tezi). Selçuk Üniversitesi, Sağlık Bilimleri Enstitüsü, Konya.
dc.identifier.urihttps://hdl.handle.net/20.500.12395/53193
dc.identifier.yoktezid859217
dc.language.isotr
dc.publisherSelçuk Üniversitesi, Sağlık Bilimleri Enstitüsü
dc.relation.publicationcategoryTez
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTekrarlanan Fırınlama
dc.subjectTranslusensi
dc.subjectMikrosertlik
dc.subjectCAD-CAM Materyaller
dc.subjectRepetitive Firings
dc.subjectTranslucency
dc.subjectMicrohardness
dc.subjectCAD-CAM Ceramic
dc.titleCam seramik CAD-CAM materyallerinde tekrarlanan fırınlama işleminin materyallerin mikrosertlik ve translusensisine olan etkisi
dc.title.alternativeThe effect of repeated firing of the glass ceramic CAD-CAM materials on the microhardness and translucency
dc.typeDoctoral Thesis

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
859217.pdf
Boyut:
3.33 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: