Resiprokal Hareket İle Kullanılan Isıl İşlem Görmüş Tek Eğe Nikel Titanyum Sistemlerin Vücut Sıcaklığında Döngüsel Yorgunluk Dirençlerinin Karşılaştırılması
dc.authorid | 0000-0002-1721-1838 | en_US |
dc.authorid | 0000-0003-3286-069X | en_US |
dc.authorid | 0000-0001-8990-4847 | en_US |
dc.authorid | 0000-0001-8899-2152 | en_US |
dc.authorid | 0000-0002-6834-4307 | en_US |
dc.contributor.author | Baş, Gözde | |
dc.contributor.author | Yüzgüleç, Elçin | |
dc.contributor.author | Keskin, Cangül | |
dc.contributor.author | İnan, Uğur | |
dc.contributor.author | Keleş, Ali | |
dc.date.accessioned | 2023-01-18T08:55:08Z | |
dc.date.available | 2023-01-18T08:55:08Z | |
dc.date.issued | 2021 | en_US |
dc.department | Başka Kurum | en_US |
dc.description.abstract | Amaç: Bu çalışmanın amacı WaveOne Gold, Reciproc Blue ve North Profa RC Blue nikel titanyum (NiTi) tek eğe döner sistemlerin vücut sıcaklığında döngüsel yorgunluğa bağlı kırılma dirençlerinin ve faz değişim derecelerinin karşılaştırılmasıdır. Gereç ve Yöntemler: Bu çalışmada 12 WaveOne Gold, 12 Reciproc Blue ve 12 North Profa RC Blue döner eğe sistem NiTi eğeleri kullanıldı. Tüm eğeler, 60°’lik kurvatür açısına, 5 mm kurvatür yarıçapına ve 1.4 mm kanal iç çapına sahip seramik yapay kanal içeren statik döngüsel yorgunluk deney düzeneğinde 37°C’de kırılıncaya kadar kullanıldı. Eğelerin kırılma zamanı dijital kronometre ile kaydedildi ve kırılıncaya kadarki tur sayıları hesaplandı. Normal dağılım göstermediği saptanan veriler Kruskal-Wallis H testi ile analiz edildi. Tahmini sağlam kalma oranının belirlenmesi için Weibull analizi yapıldı. Bulgular: North Profa RC Blue grubu ile Reciproc Blue grubu arasında ve Reciproc Blue grubu ile WaveOne Gold grubu arasında döngüsel yorgunluk direnci bakımından istatistiksel olarak anlamlı bir fark görülmedi (p>0.05). North Profa RC Blue eğelerin döngüsel yorgunluk direnci WaveOne Gold eğelerden istatistiksel olarak anlamlı derecede yüksek bulundu (p<0.05). Kırık yüzeylerden alınan SEM görüntüleri incelenerek aletlerin döngüsel yorgunluk sonucunda kırıldığı doğrulandı. Sonuç: Bu çalışmada, North Profa RC Blue ve Reciproc Blue eğelerin döngüsel yorgunluk dirençleri arasında fark bulunmazken, WaveOne Gold eğelerin döngüsel yorgunluk direnci North Profa RC Blue eğelerden daha düşük bulundu. | en_US |
dc.description.abstract | Background: The aim of this study was to compare the phase transformation temperatures and cyclic fatigue resistances of WaveOne Gold, Reciproc Blue and North Profa RC Blue nickel titanium (NiTi) instruments at body temperature. Methods: In this study 12 WaveOne Gold, 12 Reciproc Blue and 12 North Profa RC Blue rotary system NiTi files were used. All instruments were used in a static cyclic fatigue testing device, which has an artificial ceramic canal with a radius of curvature of 5 mm, an angle of curvature of 60° and a 1,4 mm inner diameter at 37°C until the fracture occurred. The time to failure of the files was recorded using a digital chronometer and the number of cycles to failure of files were calculated. Non-normally distributed data were analyzed by Kruskal-Wallis H test. Weibull analysis was performed to determine the estimated survival rate. Results: There was no statistically significant difference between the North Profa RC Blue group and the Reciproc Blue group, and between the Reciproc Blue group and the WaveOne Gold group in terms of cyclic fatigue resistance (p>0.05). Cyclic fatigue resistance of North Profa RC Blue group was statistically higher than WaveOne Gold group (p<0.05). SEM images taken from fractured surfaces confirmed that the instrument fracture occurred as the result of cyclic fatigue. Conclusion: In this study, no difference was found between the cyclic fatigue resistances of North Profa RC Blue and Reciproc Blue instruments, while the cyclic fatigue resistance of the WaveOne Gold instruments was found to be lower than the North Profa RC Blue. | en_US |
dc.identifier.citation | Baş, G., Yüzgüleç, E., Keskin, C., İnan, U., Keleş, A., (2021). Resiprokal Hareket İle Kullanılan Isıl İşlem Görmüş Tek Eğe Nikel Titanyum Sistemlerin Vücut Sıcaklığında Döngüsel Yorgunluk Dirençlerinin Karşılaştırılması. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 8 (3), 658-664. Doi: 10.15311/selcukdentj.760048 | en_US |
dc.identifier.doi | 10.15311/selcukdentj.760048 | en_US |
dc.identifier.endpage | 664 | en_US |
dc.identifier.issn | 2148-7529 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 658 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/44900 | |
dc.identifier.volume | 8 | en_US |
dc.language.iso | tr | en_US |
dc.publisher | Selçuk Üniversitesi | en_US |
dc.relation.ispartof | Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Başka Kurum Yazarı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | North Profa | en_US |
dc.subject | Reciproc Blue | en_US |
dc.subject | Seramik kanal | en_US |
dc.subject | Taramalı elektron mikroskobu | en_US |
dc.subject | WaveOne Gold | en_US |
dc.subject | Ceramic canal | en_US |
dc.subject | North Profa | en_US |
dc.subject | Scanning electron microscope | en_US |
dc.subject | WaveOne Gold | en_US |
dc.title | Resiprokal Hareket İle Kullanılan Isıl İşlem Görmüş Tek Eğe Nikel Titanyum Sistemlerin Vücut Sıcaklığında Döngüsel Yorgunluk Dirençlerinin Karşılaştırılması | en_US |
dc.title.alternative | Comparison of Cyclic Fatigue Resistance of Thermal Treated Nickel Titanium Single File Systems Used with Reciprocating Motion at Body Temperature | en_US |
dc.type | Article | en_US |