Comparison of central corneal thickness measurements in normal and keratoconic eyes using ultrasonic pachymetry and OCULUS pentacam [Normal ve keratokonuslu gölerde ultrasonik pakimetri ve OCULUS pentacam ile ölçülen santral kornea kalınlıklarının karşılaştırılması]

dc.contributor.authorBüyük K.
dc.contributor.authorBozkurt B.
dc.contributor.authorKamiş Ü.
dc.contributor.authorÖzka?nici A.
dc.contributor.authorOkudan S.
dc.date.accessioned2020-03-26T18:22:01Z
dc.date.available2020-03-26T18:22:01Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractPurpose: To compare the central corneal thickness (CCT) measurements in normal and keratoconic eyes using ultrasonic pachymetry (Ocuscan® RxP) and OCULUS Pentacam Scheimpflug camera. Material and Method: In this prospective study, CCT measurements were done in 57 keratoconic eyes and 62 healthy eyes by OCULUS Pentacam and ultrasonic pachymetry, consecutively. The measurements taken by the 2 instruments were compared with paired-samples t-test. A p value <0.05 was considered as statistically significant. The correlation between the measurements was evaluated using the Pearson test. Results: The mean CCT of keratoconic eyes was 480.18±33.6 ±m with Pentacam and 465.67±34.5 ±m with ultrasonic pachymetry, which demonstrates a statistically significant difference (t=-5.87; p585 ±m (t=-3.3; p=0.005). There was a high correlation between the CCT readings done by the two methods (r=0.95, p<0.001). Discussion: The CCT measurements obtained by Pentacam in both keratoconic and healthy eyes highly correlated with the ultrasonic measurements. However, the CCT measurements taken by Pentacam were higher compared to the ultrasonic measurements; therefore, one and the same imaging technique should be used in follow-up measurements.en_US
dc.identifier.doi10.4274/tjo.41.21en_US
dc.identifier.endpage107en_US
dc.identifier.issn1300-0659en_US
dc.identifier.issue2en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage104en_US
dc.identifier.urihttps://dx.doi.org/10.4274/tjo.41.21
dc.identifier.urihttps://hdl.handle.net/20.500.12395/27076
dc.identifier.volume41en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTurkish Ophthalmology Societyen_US
dc.relation.ispartofTurk Oftalmoloiji Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectCentral corneal thicknessen_US
dc.subjectKeratoconusen_US
dc.subjectOCULUS pentacamen_US
dc.subjectUltrasonic pachymetry (Ocuscan RxP)en_US
dc.titleComparison of central corneal thickness measurements in normal and keratoconic eyes using ultrasonic pachymetry and OCULUS pentacam [Normal ve keratokonuslu gölerde ultrasonik pakimetri ve OCULUS pentacam ile ölçülen santral kornea kalınlıklarının karşılaştırılması]en_US