Segmental kanin retraksiyonunda prefabrike Ladanyi spring ve reverse closing loop’un karşılaştırılmas

dc.authorid0000-0002-5874-9474en_US
dc.authorid0000-0002-8029-4074en_US
dc.contributor.authorKök, Hatice
dc.contributor.authorGöyenç, Yaşar Bedii
dc.date.accessioned2022-12-23T12:41:49Z
dc.date.available2022-12-23T12:41:49Z
dc.date.issued2019en_US
dc.departmentBaşka Kurumen_US
dc.description.abstractSegmental kanin retraksiyonunda prefabrike Ladanyi spring ve reverse closing loop’un karşılaştırılması Amaç: Prefabrike Ladanyi springin, elde bükümü yapılmış olan reverse closing loop ile kıyaslanması, ankraj dişler ve kaninler üzerinde meydana gelen değişimleri değerlendirmektir. Gereç ve Yöntemler: Çalışmaya ortalama yaşları 15 yıl 10 ay olan (12 yıl 6 ay-16 yıl 11 ay) 9 kız, 3 erkek toplam 12 hasta dahil edilmiştir. Prefabrike Ladanyi spring hastaların üst çenelerinde sağ segmente, reverse closing loop ise üst çenede sol segmente yerleştirilmiştir. Seanslar 4 haftada bir yapılmıştır. Her hastadan referans telleri yerleştirilerek sefalometrik radyograflar alınmıştır. Periyotlara göre sağ ve sol fark karşılaştırılmasında 2-bağımsız örnek testi Mann-Whitney U analizi, periyotlar arası kıyaslama için Friedman testi kullanılmıştır. Bulgular: Ladanyi spring grubunda 5,87 mm kanin retraksiyonu 1,37 mm molar ankraj kaybı, reverse closing loop grubunda ise 4,16 mm kanin retraksiyonu 0,75 mm molar ankraj kaybı gözlenmiştir. Ladanyi spring grubunda SN düzlemine göre kaninlerde 1,04 mm intruzyon, molarlarda 0,66 mm ekstruzyon gözlenirken reverse closing loop grubunda kanin intruzyon miktarının ortalama 0,20 mm ve molar ekstruzyon miktarının 0,04 mm olduğu tespit edilmiştir. Sonuç: Çalışmamızda Ladanyi spring grubunda kanin retraksiyonu daha hızlı gerçekleşmiştir. Her iki gruptada kanin retraksiyonu sonrasında molar dişlerde ankraj kaybı, SN düzlemine göre kaninlerde intruzyon-molarlarda ekstruzyon ve overjette spontan düzelme gözlenmiştir. Ayrıca kaninlerde distale devrilme, molarlarda meziale devrilme gözlenmiştir. Reverse closing loop ile kanin retraksiyonunun daha yavaş olmasına rağmen, daha kontrollü bir hareket sağlandığı tespit edilmiştir.en_US
dc.description.abstractComparison of prefabricated Ladanyi springs and reverse closing loop in segmental canine retraction Background: The purpose of the study is the comparison of the usage effects of prefabricated Ladanyi spring with handmade reverse closing loop, on canines and anchorage teeth. Methods: Patients,average age were 15 years 10 months,9 female-3 male were included in the study. The prefabricated springs of Ladanyi springs were inserted on patients’ right side teeth and reverse closing loops were inserted on patients’ left side. Reference wires installed cephalometric radiographs were taken.In the comparison of the difference according to periods between left and right segments 2 independent sample test Mann-Whitney U analysis has been used. Friedman Test has been used for the comparison of periods. Results: In the Ladanyi spring group 5,87 mm canine retraction 1,37 mm molar anchorage loss and in the reverse closing loop group 4,16 mm canine retraction 0,75 mm molar anchorage loss were observed. In the Ladanyi spring group 1,04 mm canine intrusion 0,66 mm molar extrusion and in the reverse closing loop group 0,20 mm canine intrusion 0,04 mm molar extrusion were observed according to SN plane. Conclusion: Our results showed that canine retraction duration was shorter in the Ladanyi group. After the canine retaction, anchorage loss in the molar teeth, according to SN plane canine intrusion and molar extrusion were noted in both groups. Despite the slower canine retraction movement with the reverse closing loop, it was provide a more controlled movement.en_US
dc.identifier.citationKök, H., Göyenç, Y. B., (2019). Segmental kanin retraksiyonunda prefabrike Ladanyi spring ve reverse closing loop’un karşılaştırılması. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 6 (1), 44-51. Doi: 10.15311/selcukdentj.528715en_US
dc.identifier.doi10.15311/selcukdentj.528715en_US
dc.identifier.endpage51en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue1en_US
dc.identifier.startpage44en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/44027
dc.identifier.volume6en_US
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Başka Kurum Yazarıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectDiş hareketien_US
dc.subjectkanin dişen_US
dc.subjectmolar dişen_US
dc.subjectortodontik boşluk kapamaen_US
dc.subjectTooth movementen_US
dc.subjectcanine toothen_US
dc.subjectmolar toothen_US
dc.subjectorthodontic space closureen_US
dc.titleSegmental kanin retraksiyonunda prefabrike Ladanyi spring ve reverse closing loop’un karşılaştırılmasen_US
dc.title.alternativeComparison of prefabricated Ladanyi springs and reverse closing loop in segmental canine retractionen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2019-7-sayı1-diş.pdf
Boyut:
1.15 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: