A calix[4]arene derivative-doped perchlorate-selective membrane electrodes with/without multi-walled carbon nanotubes

dc.contributor.authorErturun, H. Elif Kormali
dc.contributor.authorÖzel, Ayça Demirel
dc.contributor.authorAyanoğlu, Melek Nur
dc.contributor.authorŞahin, Özlem
dc.contributor.authorYılmaz, Mustafa
dc.date.accessioned2020-03-26T19:33:23Z
dc.date.available2020-03-26T19:33:23Z
dc.date.issued2017
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractIn this study, poly (vinyl chloride)(PVC) membrane electrodes with/without multi-walled carbon nanotubes (MWCNTs) based on a calix[4]arene derivative for perchlorate ion were described. The influence of membrane composition, pH, conditioning solution on the potentiometric response of the electrodes was investigated. Perchlorate-selective PVC membrane electrode exhibited a slope of 47.8 +/- 0.6 mV/pClO(4) in the range of 1.0 x 10(-7)-1.0 x 10(-1) mol L-1 at pH 4.0 while the coated Pt electrodes with MWCNT-OH, MWCNT-COOH and MWCNT displayed slopes of 46.1 +/- 0.7 mV/pClO(4) (5.0 x 10(-6)-1.0 x 10(-1) mol L-1), 50.4 +/- 1.9 mV/pClO(4) (1.0 x 10(-6)-1.0 x 10(-1) mol L-1) and 44.4 +/- 0.3 mV/pClO(4) (1.0 x 10(-5)-1.0 x 10(-1) mol L-1), respectively. Other response characteristics of these electrodes such as response time, lifetime and detection limit were identified, and the selectivity coefficients towards various anions were calculated by separate solution method. Moreover, the perchlorate-selective electrodes described here were successfully used as an indicator electrode for the determination of perchlorate in real samples such as tap water, river water and human urine by direct calibration method.en_US
dc.description.sponsorshipAnkara University Scientific Research Projects Coordination UnitAnkara University [13L4240007, 10B4240003]en_US
dc.description.sponsorshipThe authors gratefully acknowledge Ankara University Scientific Research Projects Coordination Unit in providing financial support by project no: 13L4240007 and project no: 10B4240003.en_US
dc.identifier.doi10.1007/s11581-016-1906-8en_US
dc.identifier.endpage927en_US
dc.identifier.issn0947-7047en_US
dc.identifier.issn1862-0760en_US
dc.identifier.issue4en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage917en_US
dc.identifier.urihttps://dx.doi.org/10.1007/s11581-016-1906-8
dc.identifier.urihttps://hdl.handle.net/20.500.12395/34707
dc.identifier.volume23en_US
dc.identifier.wosWOS:000399829200013en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSPRINGER HEIDELBERGen_US
dc.relation.ispartofIONICSen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectPerchlorate-selective electrodeen_US
dc.subjectCalix[4]areneen_US
dc.subjectPotentiometryen_US
dc.subjectPerchlorate determinationen_US
dc.titleA calix[4]arene derivative-doped perchlorate-selective membrane electrodes with/without multi-walled carbon nanotubesen_US
dc.typeArticleen_US