Evaluation of 1,10-phenanthroline-5,6-dione as redox mediator for glucose oxidase

dc.contributor.authorZor, Erhan
dc.contributor.authorOztekin, Yasemin
dc.contributor.authorRamanaviciene, Almira
dc.contributor.authorAnusevicius, Zilvinas
dc.contributor.authorVoronovic, Jaroslav
dc.contributor.authorBingol, Haluk
dc.contributor.authorBarauskas-Memenas, Dana
dc.date.accessioned2020-03-26T19:24:02Z
dc.date.available2020-03-26T19:24:02Z
dc.date.issued2016
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractA low-cost and simply fabricated amperometric glucose biosensor based on glucose oxidase (GOx) and 1,10-phenanthroline-5,6-dione (PD) modified graphite rod electrode was developed. The electrode exhibited good electrocatalytic activity with a well-defined hyperbolic dependence of amperometric signal upon glucose concentration in the presence and in the absence of oxygen. The electrode showed a good reproducibility and repeatability with relative standard deviation of less than 3 and 5%, respectively. The interaction of GOx with PD mediator was confirmed by means of UV?Vis absorbance spectroscopy.en_US
dc.description.sponsorshipLithuanian Scientific Council [TRY-060]; LaMeTech program [VP1-3.1-SMM-08-K-01-004/KS-120000-1756]en_US
dc.description.sponsorshipYasemin Oztekin is grateful to Lithuanian Scientific Council project No. TRY-060, Almira Ramanaviciene and Arunas Ramanavicius are grateful to LaMeTech program project No. VP1-3.1-SMM-08-K-01-004/KS-120000-1756 for financial support.en_US
dc.identifier.doi10.1134/S1061934816010044en_US
dc.identifier.endpage81en_US
dc.identifier.issn1061-9348en_US
dc.identifier.issn1608-3199en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage77en_US
dc.identifier.urihttps://dx.doi.org/10.1134/S1061934816010044
dc.identifier.urihttps://hdl.handle.net/20.500.12395/33563
dc.identifier.volume71en_US
dc.identifier.wosWOS:000367261200010en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherMAIK NAUKA/INTERPERIODICA/SPRINGERen_US
dc.relation.ispartofJOURNAL OF ANALYTICAL CHEMISTRYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectphenanthroline derivativeen_US
dc.subject1,10-phenanthroline-5,6-dioneen_US
dc.subjectglucose oxidaseen_US
dc.subjectglucose biosensoren_US
dc.subjectamperometric sensorsen_US
dc.subjectelectrocatalytic activityen_US
dc.titleEvaluation of 1,10-phenanthroline-5,6-dione as redox mediator for glucose oxidaseen_US
dc.typeArticleen_US

Dosyalar