Evaluation of 1,10-phenanthroline-5,6-dione as redox mediator for glucose oxidase
dc.contributor.author | Zor, Erhan | |
dc.contributor.author | Oztekin, Yasemin | |
dc.contributor.author | Ramanaviciene, Almira | |
dc.contributor.author | Anusevicius, Zilvinas | |
dc.contributor.author | Voronovic, Jaroslav | |
dc.contributor.author | Bingol, Haluk | |
dc.contributor.author | Barauskas-Memenas, Dana | |
dc.date.accessioned | 2020-03-26T19:24:02Z | |
dc.date.available | 2020-03-26T19:24:02Z | |
dc.date.issued | 2016 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | A low-cost and simply fabricated amperometric glucose biosensor based on glucose oxidase (GOx) and 1,10-phenanthroline-5,6-dione (PD) modified graphite rod electrode was developed. The electrode exhibited good electrocatalytic activity with a well-defined hyperbolic dependence of amperometric signal upon glucose concentration in the presence and in the absence of oxygen. The electrode showed a good reproducibility and repeatability with relative standard deviation of less than 3 and 5%, respectively. The interaction of GOx with PD mediator was confirmed by means of UV?Vis absorbance spectroscopy. | en_US |
dc.description.sponsorship | Lithuanian Scientific Council [TRY-060]; LaMeTech program [VP1-3.1-SMM-08-K-01-004/KS-120000-1756] | en_US |
dc.description.sponsorship | Yasemin Oztekin is grateful to Lithuanian Scientific Council project No. TRY-060, Almira Ramanaviciene and Arunas Ramanavicius are grateful to LaMeTech program project No. VP1-3.1-SMM-08-K-01-004/KS-120000-1756 for financial support. | en_US |
dc.identifier.doi | 10.1134/S1061934816010044 | en_US |
dc.identifier.endpage | 81 | en_US |
dc.identifier.issn | 1061-9348 | en_US |
dc.identifier.issn | 1608-3199 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopusquality | Q4 | en_US |
dc.identifier.startpage | 77 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1134/S1061934816010044 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/33563 | |
dc.identifier.volume | 71 | en_US |
dc.identifier.wos | WOS:000367261200010 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | MAIK NAUKA/INTERPERIODICA/SPRINGER | en_US |
dc.relation.ispartof | JOURNAL OF ANALYTICAL CHEMISTRY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | phenanthroline derivative | en_US |
dc.subject | 1,10-phenanthroline-5,6-dione | en_US |
dc.subject | glucose oxidase | en_US |
dc.subject | glucose biosensor | en_US |
dc.subject | amperometric sensors | en_US |
dc.subject | electrocatalytic activity | en_US |
dc.title | Evaluation of 1,10-phenanthroline-5,6-dione as redox mediator for glucose oxidase | en_US |
dc.type | Article | en_US |