Polyphenol-modified glassy carbon electrodes for copper detection

dc.contributor.authorOztekin, Yasemin
dc.contributor.authorYazicigil, Zafer
dc.contributor.authorRamanaviciene, Almira
dc.contributor.authorRamanavicius, Arunas
dc.date.accessioned2020-03-26T18:15:40Z
dc.date.available2020-03-26T18:15:40Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractThe present work reports the preparation of electrochemically polymerized flavone - luteolin and flavonol - kaempferol modified glassy carbon (GC) electrodes (PolyLut/GC and PolyKae/GC, respectively). Electrochemical polymerization was performed by electrochemical oxidation of luteolin and kaempferol by potential cycling in aqueous media. Cyclic voltammograms of luteolin on the GC electrode indicated one clear oxidation peak at +475 mV, which can be assigned to the oxidation of 3'-hydroxyl and 4'-hydroxyl groups in the B-ring of the luteolin molecule. The cyclic voltammograms of kaempferol on the GC electrode contained two oxidation peaks, one at about +390 mV, which is assigned to the oxidation of 4'-hydroxyl and 3-hydroxyl groups of the B-ring and C-ring of the kaempferol molecule, and second oxidation peak at about +710 mV, which is assigned to the 7-hydroxyl group of the A-ring. The interaction of PolyLut/GC and PolyKae/GC electrodes with copper(II) (Cu(II)) ions were investigated by differential pulse voltammetry (DPV). It was determined that PolyLut/GC and PolyKae/GC electrodes showed sensitivity towards Cu(II) with good reproducibility and stability of analytical signal. The effect of the interfering ions on the voltammetric measurements of Cu(II) was examined. (c) 2010 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipSelcuk University Research FoundationSelcuk University [09401039]en_US
dc.description.sponsorshipThe authors would like to thank to Selcuk University Research Foundation for the financial support provided by under the project number 09401039.en_US
dc.identifier.doi10.1016/j.snb.2010.09.057en_US
dc.identifier.endpage48en_US
dc.identifier.issn0925-4005en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage37en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.snb.2010.09.057
dc.identifier.urihttps://hdl.handle.net/20.500.12395/26728
dc.identifier.volume152en_US
dc.identifier.wosWOS:000288189100006en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE SAen_US
dc.relation.ispartofSENSORS AND ACTUATORS B-CHEMICALen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectElectrochemical surface modificationen_US
dc.subjectElectrochemical determination of copper(II)en_US
dc.subjectElectrochemical polymerizationen_US
dc.subjectKaempferolen_US
dc.subjectLuteolinen_US
dc.titlePolyphenol-modified glassy carbon electrodes for copper detectionen_US
dc.typeArticleen_US

Dosyalar