Evaluation of Biodegradable Fixation System for Mandibular Angulus Fracture by Using Finite Element Method

dc.contributor.authorAy, M.
dc.contributor.authorHartomacioglu, S.
dc.contributor.authorBakircioglu, B.
dc.contributor.authorYuzbasioglu, H. E.
dc.contributor.authorKubat, T.
dc.date.accessioned2020-03-26T19:24:03Z
dc.date.available2020-03-26T19:24:03Z
dc.date.issued2016
dc.departmentSelçuk Üniversitesien_US
dc.description5th International Advances in Applied Physics and Materials Science Congress and Exhibition (APMAS) -- APR 16-19, 2015 -- Oludeniz, TURKEYen_US
dc.description.abstractTo date many fixation techniques of mandibular angle fractures have been introduced. There exist much research on the stability of plate and screws systems used in Champy technique in fixation of mandibular fractures. However the need of a second surgery for the removal of these plates and screws, and well known disadvantages of metallic fixations have led to the development of resorbable materials. It is thought that in order to achieve a safe and effective post-operative stability, the use of resorbable plates and screws is preferred for fixation. In this study, fixation evaluation of biodegradable plates which have been commonly used in recent years, was investigated using finite element method. 3D model required to perform the finite element analysis was obtained from CT scanning images using reverse engineering methods and material properties of mandible were obtained by Hounsfield Unit method. Biodegradable fixation systems were applied to this model and FEA was performed. It is concluded that biodegradable plate screw system used in the treatment of mandibular angle fractures shows a sufficient stability under masticatory forces.en_US
dc.identifier.doi10.12693/APhysPolA.129.883en_US
dc.identifier.endpage885en_US
dc.identifier.issn0587-4246en_US
dc.identifier.issn1898-794Xen_US
dc.identifier.issue4en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage883en_US
dc.identifier.urihttps://dx.doi.org/10.12693/APhysPolA.129.883
dc.identifier.urihttps://hdl.handle.net/20.500.12395/33565
dc.identifier.volume129en_US
dc.identifier.wosWOS:000376595000124en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPOLISH ACAD SCIENCES INST PHYSICSen_US
dc.relation.ispartofACTA PHYSICA POLONICA Aen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleEvaluation of Biodegradable Fixation System for Mandibular Angulus Fracture by Using Finite Element Methoden_US
dc.typeArticleen_US

Dosyalar