A new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite film for simultaneous determination of catechol and hydroquinone

Küçük Resim Yok

Tarih

2015

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

PERGAMON-ELSEVIER SCIENCE LTD

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Catechol (1,2-dihydroxybenzene) and hydroquinone (1,4-dihydroxybenzene) are two isomers of phenolic compounds which often coexist and interfere with each other during their identification in environmental samples. This study presents simultaneous determination of catechol (CC) and hydroquinone (HQ) using a new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite (AuNPs/Fe3O4-APTES-GO). CV results show well-defined oxidation peaks with anodic peaks at 0.15 V for CC and 0.05 V for HQ, and the peak-to-peak separation for CC and HQ is about 100 mV. Under the optimized conditions, the current response of AuNPs/Fe3O4-APTES-GO/GCE is linear for CC and HQ in the range of 2-145 mu M and 3-137 mu M, respectively. The detection limits for CC and HQ were found to be 0.8 mu M and 1.1 mu M, respectively. The fabricated sensor was successfully applied for the determination of CC and HQ in tap water sample with satisfactory recovery. (C) 2015 Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

catechol, hydroquinone, gold electrodeposition, iron oxide, graphene oxide

Kaynak

ELECTROCHIMICA ACTA

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

186

Sayı

Künye