Detection of Rotor Bar Faults by Using Stator Current Envelope
dc.contributor.author | Arabaci, Hayri | |
dc.contributor.author | Bilgin, Osman | |
dc.date.accessioned | 2020-03-26T18:14:05Z | |
dc.date.available | 2020-03-26T18:14:05Z | |
dc.date.issued | 2011 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description | World Congress on Engineering (WCE 2011) -- JUL 06-08, 2011 -- Imperial Coll, London, UNITED KINGDOM | en_US |
dc.description.abstract | The paper presents detection of rotor bar faults at steady state operation in squirrel cage induction motor by using stator current envelope. Three different rotor faults and healthy motor conditions were investigated in experiments. One of the stator currents has been used in the investigation of effects of rotor faults on the current envelope. The ratios of fluctuation of the envelope were used as feature of fault conditions for diagnosis. In the literature a lot of studies are available about diagnosis and detection rotor many different analysis and feature extraction methods such as motor current signature analysis (MCSA), fast Fourier transform (FFT). Unlike the literature, in the present study the stator current envelopes are used. The use of the current envelope does not affect the performance of the fault detection, while requiring much less computation and low cost in implementation, which would make it easier to implement in embedded systems for condition monitoring of motor. | en_US |
dc.description.sponsorship | Int Assoc Engineers, IAENG, Soc Artificial Intelligence, IAENG, Soc Bioinformat, IAENG, Soc Computer Sci, IAENG, Soc Data Min, IAENG, Soc Elect Engn, IAENG, Soc Imagl Engn, IAENG, Soc Ind Engn, IAENG, Soc Informat Syst Engn, IAENG, Soc Internet Comput & Web Serv, IAENG, Soc Mech Engn, IAENG, Soc Operat Res, IAENG, Soc Sci Comput, IAENG, Soc Software Engn, IAENG, Soc Wireless Engn | en_US |
dc.description.sponsorship | Scientific Research Project of Selcuk UniversitySelcuk University | en_US |
dc.description.sponsorship | The study has been supported by Scientific Research Project of Selcuk University. | en_US |
dc.identifier.endpage | 1435 | en_US |
dc.identifier.isbn | 978-988-19251-4-5 | |
dc.identifier.issn | 2078-0958 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 1432 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/26301 | |
dc.identifier.wos | WOS:000393012800101 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | INT ASSOC ENGINEERS-IAENG | en_US |
dc.relation.ispartof | WORLD CONGRESS ON ENGINEERING, WCE 2011, VOL II | en_US |
dc.relation.ispartofseries | Lecture Notes in Engineering and Computer Science | |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Broken rotor bar | en_US |
dc.subject | fault diagnosis | en_US |
dc.subject | induction motors | en_US |
dc.subject | motor current signature analysis | en_US |
dc.subject | stator current envelope | en_US |
dc.title | Detection of Rotor Bar Faults by Using Stator Current Envelope | en_US |
dc.type | Conference Object | en_US |