Separation of some priority organic pollutants in wastewater samples by column chromatography
Yükleniyor...
Tarih
2004
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
PARLAR SCIENTIFIC PUBLICATIONS (P S P)
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
The aim of this work was to develop a fractionation procedure to separate PCBs and PAHs in wastewater extracts, while simultaneously eliminating the interfering substances, a necessary precondition for analysis with nonselective GC detectors. This was carried out by optimizing the fraction cut-off volume of the eluting solvent and deactivation levels of different adsorbents for column chromatography. Using a combined column (5 g aluminum oxide, deactivated with 5% H2O plus 5 g fully activated silica gel) and cutting off PCB collection, after elution with 50 mL n-hexane, led to satisfactory separation of PCBs and PAHs. The approach of this study was to decrease solvent volume and analysis time during cleanup procedure compared to the US EPA standard methods (EPA Methods 610 and 608 for PAHs and PCBs, respectively).
Açıklama
Anahtar Kelimeler
PCB, PAH, fractionation, column chromatography
Kaynak
FRESENIUS ENVIRONMENTAL BULLETIN
WoS Q Değeri
Q4
Scopus Q Değeri
N/A
Cilt
13
Sayı
7