Separation of some priority organic pollutants in wastewater samples by column chromatography

Yükleniyor...
Küçük Resim

Tarih

2004

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

PARLAR SCIENTIFIC PUBLICATIONS (P S P)

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

The aim of this work was to develop a fractionation procedure to separate PCBs and PAHs in wastewater extracts, while simultaneously eliminating the interfering substances, a necessary precondition for analysis with nonselective GC detectors. This was carried out by optimizing the fraction cut-off volume of the eluting solvent and deactivation levels of different adsorbents for column chromatography. Using a combined column (5 g aluminum oxide, deactivated with 5% H2O plus 5 g fully activated silica gel) and cutting off PCB collection, after elution with 50 mL n-hexane, led to satisfactory separation of PCBs and PAHs. The approach of this study was to decrease solvent volume and analysis time during cleanup procedure compared to the US EPA standard methods (EPA Methods 610 and 608 for PAHs and PCBs, respectively).

Açıklama

Anahtar Kelimeler

PCB, PAH, fractionation, column chromatography

Kaynak

FRESENIUS ENVIRONMENTAL BULLETIN

WoS Q Değeri

Q4

Scopus Q Değeri

N/A

Cilt

13

Sayı

7

Künye