The effect of stirrups and hooked steel fibers instead on moment-rotation capacity of beam-column connections

dc.contributor.authorAkın, Süleyman Kamil
dc.contributor.authorKara, Nail
dc.date.accessioned2018-05-23T09:00:18Z
dc.date.available2018-05-23T09:00:18Z
dc.date.issued2008
dc.descriptionURL: http://sutod.selcuk.edu.tr/sutod/article/view/61en_US
dc.description.abstractIn earthquakes the energy should be dissipated by structural elements. The energy concentrated in beam-column connections and the earthquake loads forces the connections to rotate. As a result of this, the connections should have the ability of rotation without reduction in axial load capacity of columns. The concrete in the connection zone should not break, collapse and should stay stiff for no reduction in the load bearing capacity of connection. Because of this all codes forces design engineer and constructor to continue stirrups in beam or column without break in the connection. While application of reinforcement according to the design in construction stage , to put stirrups in connection is very hard and takes a lot of time also it is very hard to concrete this region also. This study concerns with the use of hooked steel fibers instead of stirrups in beam column connections. Recent studies made clear that , use of steel fibers increase ductility, stiffness and toughness in concrete[1] [2] [3] [4]. In this study 5 beam-column connections are tested under cyclic loading. First specimen has stirrups in connection zone according to code, the rest have no stirrups but have hooked steel fibers instead in connection zone with varying volumetric ratio 0,000%, 0,250%, 0,375%, 0,500%. The specimens are tested in Selcuk University Civil Engineering Department Structural Laboratory. Earthquake loads are simulated on the 1/1-scaled specimens and all vertical and horizontal displacements are taken by a dozen of LVDT and this data is sent and saved by the help of an electronic device and computer program. The experimental moment and rotation capacities are found and compared.en_US
dc.identifier.citationAkın, S. K., Kara, N. (2008). The effect of stirrups and hooked steel fibers instead on moment-rotation capacity of beam-column connections. Selçuk-Teknik Dergisi, 7, (2), 218-226.en_US
dc.identifier.endpage226
dc.identifier.issn1302-6178en_US
dc.identifier.startpage218
dc.identifier.urihttps://hdl.handle.net/20.500.12395/10783
dc.identifier.volume7
dc.language.isoenen_US
dc.publisherSelçuk Üniversitesi Teknik Bilimler Meslek Yüksekokuluen_US
dc.relation.ispartofSelçuk-Teknik Dergisien_US
dc.relation.publicationcategoryMakale - Kategori Belirleneceken_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectStirrupen_US
dc.subjectHooked steel fiberen_US
dc.subjectBeam column connectionen_US
dc.subjectÇengel çelik elyafen_US
dc.subjectKiriş kolon bağlantısıen_US
dc.subjectÜzengien_US
dc.titleThe effect of stirrups and hooked steel fibers instead on moment-rotation capacity of beam-column connectionsen_US
dc.title.alternativeEtriye ve yerine kullanılan kancalı çelik tellerin kolon-kiriş birleşim bölgelerinde moment-dönme kapasitesine etkilerien_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
S.Kamil AKIN Nail KARA.pdf
Boyut:
781.61 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.51 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: