Experimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysis

dc.contributor.authorDincer, K.
dc.contributor.authorYilmaz, Y.
dc.contributor.authorBerber, A.
dc.contributor.authorBaskaya, S.
dc.date.accessioned2020-03-26T18:14:38Z
dc.date.available2020-03-26T18:14:38Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractIn this study, three Ranque-Hilsch vortex tubes were used, which have 9 mm inside diameter and length/diameter ratio was 15. Their performances were examined as one of the classical RHVT and other was hot cascade type RHVT. Performance analysis was according to temperature difference between the hot outlet and the inlet (Delta T-hot.). The Delta T-hot values of hot cascade type Ranque-Hilsch vortex tubes were greater than the Delta T-hot values of classical RHVT, which were determined experimentally. The total inlet exergy, total outlet exergy, total lost exergy and exergy efficiency of hot stream were investigated by using experimental data. In both the classical RI-PIT and hot cascade type RHVT, it was found that as fraction of cold flow increases the total lost exergy decreases. It was also found that, the hot cascade type RHVT more exergy efficiency of hot outlet than the classical RHVT. Excess Delta T-hot value of hot cascade type Ranque-Hilsch vortex tube causes the excess exergy efficiency of hot outlet. (C) 2011 Elsevier Ltd and IIR. All rights reserved.en_US
dc.description.sponsorshipSelcuk UniversitySelcuk University [BAP 08401034]en_US
dc.description.sponsorshipFinancial support of this study by the research fund of the Selcuk University under grant No. BAP 08401034 is gratefully acknowledged.en_US
dc.identifier.doi10.1016/j.ijrefrig.2011.01.017en_US
dc.identifier.endpage1124en_US
dc.identifier.issn0140-7007en_US
dc.identifier.issn1879-2081en_US
dc.identifier.issue4en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage1117en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijrefrig.2011.01.017
dc.identifier.urihttps://hdl.handle.net/20.500.12395/26483
dc.identifier.volume34en_US
dc.identifier.wosWOS:000291576500031en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.relation.ispartofINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROIDen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectRanque-Hilschen_US
dc.subjectVortex tubeen_US
dc.subjectExperimenten_US
dc.subjectExergyen_US
dc.subjectEfficiency geometryen_US
dc.titleExperimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysisen_US
dc.typeArticleen_US

Dosyalar