Farklı üretim teknikleri ile elde edilen Cr-Co metal-seramik örneklerin bağlanma dayanımının değerlendirilmesi

dc.authorid0000-0003-0927-6962en_US
dc.authorid0000-0002-7101-822Xen_US
dc.contributor.authorKarcı, Muhammet
dc.contributor.authorDemir, Necla
dc.date.accessioned2022-12-23T11:07:01Z
dc.date.available2022-12-23T11:07:01Z
dc.date.issued2019en_US
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAmaç: Dört farklı üretim tekniği (döküm, tekrarlanan döküm, CAD-CAM ve seçici lazer sinterleme) ile elde edilen Cr-Co metal seramik örneklerin (n:10) farklı pH ortamlarındaki (pH:2.3 ve pH:6.5) yapay tükrükte farklı bekletme süreleri sonundaki bağlanma dayanımını değerlendirmektir. Gereç ve Yöntemler: Bu çalışmada 4 grupta toplam 200 Cr-Co metal seramik örnek 4 farklı teknik (döküm, tekrarlanan döküm, CAD-CAM ve seçici lazer sinterleme) ile hazırlanmıştır (n=10). Ayrıca SEM analizinde kontrol grubu olarak kullanılmak üzere Cr-Co metal alaşım örneklerinden 1’er adet her grup için üretilmiştir. Metal seramik örneklerin iki farklı pH ortamındaki (pH 2.3 ve pH 6.5) yapay tükrükte 15 ve 30 gün bekletilme sonrası makaslama bağlanma dayanımı ölçülmüştür. Her gruptan birer örnek taramalı elektron mikroskobu (SEM) analizi ile yüzey değişikliği ve kırılma morfolojisi açısından değerlendirilmiştir. Bulgular: Bağlanma dayanımı bakımından seçici lazer sinterleme tekniği CAD-CAM ve tekrarlanan döküm tekniğinden daha iyi bulunmuştur. En yüksek bağlanma dayanımı değerini döküm tekniği göstermiştir. 2.3 pH değerinde daha düşük bağlanma dayanımı bulunmuştur. Her iki pH değerinde de 30 günlük bekletme süresinde, 15 günlük bekletme süresine göre daha düşük bağlanma dayanımı sonuçları bulunmuştur. Sonuç: Döküm tekniği ilk tercih olmakla birlikte; seçici lazer sinterleme tekniği, CAD-CAM tekniğine kıyasla bağlanma dayanımı bakımından tercih edilebilir. Ortamın asiditesinin bekletme süresiyle doğru orantılı olarak materyalin direncini azalttığı sonucuna ulaşılabilir. Bu nedenle ani pH değişimlerine karşı metal-porselen ekspoz alanlarının ağızda bekletilmemesi gerektiği düşünülebilir.en_US
dc.description.abstractBackground: In this study, the shear bond strength of the metal ceramic samples obtained by 4 different techniques (casting, repeated casting, CAD-CAM and selective laser sintering) were measured at 15 days and 30 days after immersed in the artificial saliva at two different pH (pH:2.3 ve pH:6.5) environments. Methods: In this study, 200 Cr-Co metal ceramic samples in 4 groups were obtained by 4 different techniques (casting, repeated casting, CAD-CAM and selective laser melting). Four Cr-Co metal samples from each group were manufactured for SEM analysis as control groups. Ten samples from each group were determined for all groups (n=10). The shear bond strength of the metal ceramic samples were measured after immersed in artificial saliva at two different pH (pH 2.3 and pH 6.5) for 15 and 30 days. One sample from each group was evaluated by scanning electron microscopy (SEM) analysis in terms of surface change and fracture morphology. Results: In terms of bond strength selective laser sintering technique found to be better than the CAD-CAM and repeated casting technique. The highest bond strength values were found for the casting technique (5.7 MPa). The shear bond strength was found to be lower at 2.3 pH value (2.7 MPa). The shear bond strength value was found to be lower for 30 days than 15 days at both pH values (3.6 MPa). Conclusion: Besides the casting technique determined as the first preference, the selective laser technique can be preferred compared to the CAD-CAM technique in terms of shear bond strength. The acidity of the environment in direct proportion to the immersion period can both decrease the strength of the material. It was concluded that the metal-ceramic exposed areas should not be left in the mouth against the instant pH changes.en_US
dc.identifier.citationDemir, N., Karcı, M., (2019). Farklı üretim teknikleri ile elde edilen Cr-Co metal-seramik örneklerin bağlanma dayanımının değerlendirilmesi. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 6 (3), 347-358. Doi: 10.15311/selcukdentj.599621en_US
dc.identifier.doi10.15311/selcukdentj.599621en_US
dc.identifier.endpage358en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue3en_US
dc.identifier.startpage347en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/43991
dc.identifier.volume6en_US
dc.institutionauthorDemir, Necla
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectBağlanma dayanımıen_US
dc.subjectCAD-CAMen_US
dc.subjectiyon salınımıen_US
dc.subjectmetal-seramiken_US
dc.subjectseçici lazer sinterlemeen_US
dc.subjectBond strengthen_US
dc.subjection releaseen_US
dc.subjectmetal-ceramicen_US
dc.subjectselective laser sinteringen_US
dc.titleFarklı üretim teknikleri ile elde edilen Cr-Co metal-seramik örneklerin bağlanma dayanımının değerlendirilmesien_US
dc.title.alternativeEvaluation of bond strength of Cr-Co metal-ceramic samples produced by different techniquesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2019-13-sayı3-diş.pdf
Boyut:
960.12 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: