Farklı döner eğe sistemleri ile prepare edilmiş kök kanal dentinine 3 farklı fiber-post sisteminin itme bağ dayanımlarının değerlendirilmesi

dc.authorid0000-0002-6092-4817en_US
dc.authorid0000-0003-4862-7905en_US
dc.authorid0000-0002-5403-667Xen_US
dc.authorid0000-0002-6546-6368en_US
dc.authorid0000-0001-6976-3071en_US
dc.contributor.authorTerlemez, Arslan
dc.contributor.authorÇelebi, Hakkı
dc.contributor.authorBüyükerkmen, E. Begüm
dc.contributor.authorKorkut, Emre
dc.contributor.authorÜnlü, Nimet
dc.date.accessioned2022-12-16T11:45:20Z
dc.date.available2022-12-16T11:45:20Z
dc.date.issued2019en_US
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAmaç: Bu in vitro araştırmanın amacı, iki farklı endodontik döner eğe sistemi ile hazırlanmış kök kanallarına yerleştirilen 3 farklı fiber postun itme bağ dayanımlarının karşılaştırılmasıdır. Gereç ve Yöntemler: Kırk iki adet çekilmiş tek köklü insan alt premolar dişlerin kronları uzaklaştırıldı. Kökler 2 ana gruba ayrıldı (n=21) ve ilk gruptaki kök kanalları Wave-One ile hazırlandı ve diğeri ise TF Adaptive (SybronEndo, Orange, CA, ABD) sistemler ile hazırlandı. Daha sonra kökler üç farklı fiber post tipine göre alt gruplara ayrıldı. FRC Postec Plus (Ivoclar, Vivadent AG, Schaan, Lihtenştayn), GC Fiber Post (GC Corporation, Tokyo, Japonya) ve Rely-X (3M ESPE, Seefeld, Almanya) kullanıldı. Bütün alt gruplar birself adezivsiman (Rely-X Unicem, 3M ESPE, Seefeld, Almanya) ile yapıştırıldı. Sonra kök örnekleri su soğutma sıvısı altında düşük hızlı bir elmas disk kullanılarak, 1.00 mm ± 0.05 mm kalınlığında kesitler alındı. Evrensel bir itme testi cihazı kullanılarak 1 mm/dk'lık bir hızda itme bağ dayanım testi gerçekleştirildi ve veriler, p?0.05 seviyesinde 3 yollu ANOVA ve Tukey testi ile istatistiksel olarak analiz edildi. Bulgular: Kök kanal preperasyon tekniği, fiber postun türü ve dişin koronal, orta veya apikal bölgesinden alınan kesitler arasında bağlanma dayanımı yönünden istatistiksel olarak anlamlı bir fark olmadığı bulundu (p>0.05). Sonuç: Farklı döner eğe sistemleri ile hazırlanmış kök kanalına farklı post sistemlerinin bağlanma dayanımı arasında fark bulunmamaktadır.en_US
dc.description.abstractBackground: The purpose of this in vitro investigation was to compare of the push-out bond strength of 3 different fiber posts cemented in root canals which were prepared with 2 different endodontic rotary systems. Methods: Forty-two human extracted one rooted mandibular premolar teeth were decoronated. Roots were divided into 2 main groups (n=21) and the root canals of the first group was prepared with Wave-One and the other was prepared with TF Adaptive systems. Then roots were divided also three different fiber post subgroups. FRC Postec Plus (Ivoclar, Vivadent AG, Schaan, Liechtenstein), GC Fiber Post (GC Corporation, Tokyo, Japan), and Rely-X (3M ESPE, Seefeld, Germany) was used. All subgroups were cemented with a self-adhesive cement (Rely-X Unicem,3M ESPE, Seefeld, Germany).Root samples sectioned horizontally andthe thickness of the root dentin slices were1.00 mm ± 0.05 mm by using a low-speed diamond saw under water coolant. Push-out test was performed at a crosshead speed of 1 mm/min by using a universal testing machine, and the data was statistically analyzed with 3 way- Anova and Tukey test at p?0.05 level. Results: There were no statistically significant difference between root canal preparation technique, fiber post systems and coronalmiddle or apical third of the root about bond strength (p>0.05). Conclusion: There is no difference between the bonding strength of different post systems to the root canal prepared with different rotating file systems.en_US
dc.identifier.citationTerlemez, A., Çelebi, H., Büyükerkmen, E. B., Ünlü, N., Korkut, E., (2019). Farklı döner eğe sistemleri ile prepare edilmiş kök kanal dentinine 3 farklı fiber-post sisteminin itme bağ dayanımlarının değerlendirilmesi. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 6 (3), 254-260. Doi: 10.15311/selcukdentj.432790en_US
dc.identifier.doi10.15311/selcukdentj.432790en_US
dc.identifier.endpage260en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue3en_US
dc.identifier.startpage254en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/43904
dc.identifier.volume6en_US
dc.institutionauthorÜnlü, Nimet
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectEndodontik döner eğe sistemlerien_US
dc.subjectfiber posten_US
dc.subjectitme bağ dayanımıen_US
dc.subjectEndodontic rotary file systemsen_US
dc.subjectfiber post systemsen_US
dc.subjectpush-out bondstrengthen_US
dc.titleFarklı döner eğe sistemleri ile prepare edilmiş kök kanal dentinine 3 farklı fiber-post sisteminin itme bağ dayanımlarının değerlendirilmesien_US
dc.title.alternativeEvaluation of the push-out bond strengths of 3 different fiberpost systems in the root canal dentin prepared by different rotary file systemsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2019-2-sayı3-diş.pdf
Boyut:
864.72 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: