Dimensional changes and water sorption of two acrylic polymer materials reinforced with glass fibres.
Küçük Resim Yok
Tarih
2003
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
The purpose of this study was to examine the effect of glass fibre reinforcement on the dimensional changes and water sorption of a heat-polymerising denture acrylic polymer and a microwave-polymerising denture acrylic polymer. Fifteen specimens from each group were prepared with 2% by weight (18 mg) E-glass fibre and 15 without glass fibre. The dimensional change measurements were made at three different stages on the 60 specimens. The water sorption calculations were made on specimens immersed in distilled water at 37 degrees C +/- 1 degree C for 0, 1 and 7 days. Glass fibre reinforcement and processing method do not affect the dimensional change of test specimens, but as the time increased the dimensional change decreased. The glass fibre reinforcement decreased water sorption, but the two processing methods failed to show a significant difference.
Açıklama
Anahtar Kelimeler
Kaynak
The European journal of prosthodontics and restorative dentistry
WoS Q Değeri
Scopus Q Değeri
Q3
Cilt
11
Sayı
3