Bond strength of an adhesive system to dentin contaminated with hemostatic agents

dc.contributor.authorGüller F.
dc.contributor.authorŞimşek M.
dc.contributor.authorCebe F.
dc.contributor.authorYildiz E.
dc.contributor.authorYildirim C.
dc.date.accessioned2020-03-26T18:58:49Z
dc.date.available2020-03-26T18:58:49Z
dc.date.issued2014
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractObjectives: The aim of the present study was to evaluate the microtensile bond strength (?TBS) of self-etch adhesive system to dentin surface contaminated with three different hemostatic agents in the presence of blood and saliva. Materials and Methods: Twelve extracted human carious-free permanent molar teeth were used to obtain flat occlusal dentin surfaces. The dentin surfaces were grinded with 600 grid sandpaper under water irrigation. Teeth were divided into four groups (I: Kontrol, II: Ankaferd, III: ViscoStat Clear and IV: Transamine). The hemostatic agents were aplicated in the presence of blood and saliva, then were rinsed and dried. Teeth were restored with self-etch adhesive system (Clearfil SE Bond) 2mm thick composite resin (Quadrant Universal LC). Then specimens were stored 37 °C distilled water during 24 hours. Five microtensile specimens from each tooth measuring 1.00-+ 0.003 mm were prepared with a slow-speed diamond saw sectioning machine with a diamondrim blade (n=15). These specimens were attached to opposing arms of the microtensile testing device with cyanoacrylate adhesive and fractured under tension at a crosshead speed of 1 mm/min. Statistical analysis was made with one-way analysis of variance (ANOVA) and Tukey tests (?=0.05). Results: ?TBS values of groups were (mean ± SD in MPa); I: 28.81±6.84, II: 27.38±4.89, III: 24.89±5.80, IV: 24.73±7.14. There was no significant differences between ?TBS of groups (p>0.05). Conclusions: Contamination of dentin with hemostatic agents didn't affect the ?TBS of self-etch a dhesive system. Hemostatic agents may be used to control bleeding without decreasing ?TBS of self-etch adhesive system.en_US
dc.identifier.citationGüller, F., Şimşek, M., Cebe, F., Yıldız, E., Yıldırım, C. (2014). Bond Strength of an Adhesive System to Dentin Contaminated with Hemostatic Agents. Cumhuriyet Dental Journal, 17(1), 42-47.
dc.identifier.doi10.7126/cdj.58140.1008002098en_US
dc.identifier.endpage47en_US
dc.identifier.issn2146-2852en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage42en_US
dc.identifier.urihttps://dx.doi.org/10.7126/cdj.58140.1008002098
dc.identifier.urihttps://hdl.handle.net/20.500.12395/31300
dc.identifier.volume17en_US
dc.indekslendigikaynakScopusen_US
dc.institutionauthorCebe F.
dc.language.isotren_US
dc.relation.ispartofCumhuriyet Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectAnkaferden_US
dc.subjectDentin-bonding agentsen_US
dc.subjectTransamineen_US
dc.subjectViscostat clearen_US
dc.titleBond strength of an adhesive system to dentin contaminated with hemostatic agentsen_US
dc.title.alternativeBir adeziv sistemin kanama durdurucu ajanlarla kontamine edilen dentin yüzeyine bağlanma dayanımıen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Fatma GÜLLER.pdf
Boyut:
46.63 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Full Text Access