Investigation of Performance of Heating and Cooling of Counter Flow Ranque-Hilsch Tubes with L/D=15, 16, 17, 18 for Brass
Küçük Resim Yok
Tarih
2013
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
TRANS TECH PUBLICATIONS LTD
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study, heating and cooling performances of counter flow Ranque-Hilsch vortex tubes (RHVTs) were experimentally investigated for brass. The vortex tubes were made of brass. Diameter of vortex tube (D) was 10 mm. Length of vortex tube (L) was 15D, 16D, 17D and18D. The number of nozzles (Nn) was 5. The conical edges of the plugs have a slope of 30 degrees angle. Working pressure of Ranque-Hilsch was 460 kPa (absolute). According to the experimental results, the maximum heating performance of the RHVT system was found to be 39,5 degrees C at P-17 and the maximum cooling performance of the RHVT in this study was found to be -28,6 degrees C at P-18. An increase in fraction of cold flow (xi) led to a increase in the heating performance.
Açıklama
2nd International Conference on Advanced Materials Design and Mechanics (ICAMDM 2013) -- MAY 17-18, 2013 -- Kuala Lumpur, MALAYSIA
Anahtar Kelimeler
Ranque-Hilsch vortex tube, heating, cooling, temperature separation
Kaynak
ADVANCED MATERIALS DESIGN AND MECHANICS II