An experimental investigation on exergy analysis of an ejector expansion refrigeration system

dc.contributor.authorSag, Nagihan Bilir
dc.contributor.authorErsoy, Halil Kursad
dc.contributor.authorHepbasli, Arif
dc.date.accessioned2020-03-26T19:33:47Z
dc.date.available2020-03-26T19:33:47Z
dc.date.issued2017
dc.departmentSelçuk Üniversitesien_US
dc.description8th International Exergy, Energy and Environment Symposium (IEEES) -- MAY 01-04, 2016 -- Antalya, TURKEYen_US
dc.description.abstractUtilisation of an ejector as an expander was experimentally investigated for an expansion work recovery in a basic refrigeration cycle. Exergy analysis was used to determine the amounts and locations of irreversibilities in the elements of the ejector expansion refrigeration system. It was seen that the ejector refrigeration cycle indicated a lower exergy destruction and a higher exergy efficiency compared to the vapour compression refrigeration cycle for each working condition. It was obtained that the values for the irreversibility of the ejector refrigeration cycle were less than in the vapour compression refrigeration cycle by 5.9-12.6% and the exergy efficiencies of ejector refrigeration cycle were 6.7-14.2% more than in the vapour compression cycle.en_US
dc.description.sponsorshipTUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [110M044]en_US
dc.description.sponsorshipThis study was supported by the grant of 110M044 by the TUBITAK. Also, this paper forms part of Nagihan Bilir Sag's doctoral thesis. The authors also would like to thank the valuable reviewers and the Guest Editor for their valuable and constructive comments, which have been very useful in improving the quality of the paper.en_US
dc.identifier.doi10.1504/IJEX.2017.10008596en_US
dc.identifier.endpage215en_US
dc.identifier.issn1742-8297en_US
dc.identifier.issn1742-8300en_US
dc.identifier.issue02.04.2020en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage201en_US
dc.identifier.urihttps://dx.doi.org/10.1504/IJEX.2017.10008596
dc.identifier.urihttps://hdl.handle.net/20.500.12395/34783
dc.identifier.volume24en_US
dc.identifier.wosWOS:000414955200006en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherINDERSCIENCE ENTERPRISES LTDen_US
dc.relation.ispartofINTERNATIONAL JOURNAL OF EXERGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectirreversibilityen_US
dc.subjectejectoren_US
dc.subjectexergy analysisen_US
dc.subjectthrottlingen_US
dc.subjectexergy efficiencyen_US
dc.titleAn experimental investigation on exergy analysis of an ejector expansion refrigeration systemen_US
dc.typeArticleen_US

Dosyalar