An experimental investigation on exergy analysis of an ejector expansion refrigeration system
dc.contributor.author | Sag, Nagihan Bilir | |
dc.contributor.author | Ersoy, Halil Kursad | |
dc.contributor.author | Hepbasli, Arif | |
dc.date.accessioned | 2020-03-26T19:33:47Z | |
dc.date.available | 2020-03-26T19:33:47Z | |
dc.date.issued | 2017 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description | 8th International Exergy, Energy and Environment Symposium (IEEES) -- MAY 01-04, 2016 -- Antalya, TURKEY | en_US |
dc.description.abstract | Utilisation of an ejector as an expander was experimentally investigated for an expansion work recovery in a basic refrigeration cycle. Exergy analysis was used to determine the amounts and locations of irreversibilities in the elements of the ejector expansion refrigeration system. It was seen that the ejector refrigeration cycle indicated a lower exergy destruction and a higher exergy efficiency compared to the vapour compression refrigeration cycle for each working condition. It was obtained that the values for the irreversibility of the ejector refrigeration cycle were less than in the vapour compression refrigeration cycle by 5.9-12.6% and the exergy efficiencies of ejector refrigeration cycle were 6.7-14.2% more than in the vapour compression cycle. | en_US |
dc.description.sponsorship | TUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [110M044] | en_US |
dc.description.sponsorship | This study was supported by the grant of 110M044 by the TUBITAK. Also, this paper forms part of Nagihan Bilir Sag's doctoral thesis. The authors also would like to thank the valuable reviewers and the Guest Editor for their valuable and constructive comments, which have been very useful in improving the quality of the paper. | en_US |
dc.identifier.doi | 10.1504/IJEX.2017.10008596 | en_US |
dc.identifier.endpage | 215 | en_US |
dc.identifier.issn | 1742-8297 | en_US |
dc.identifier.issn | 1742-8300 | en_US |
dc.identifier.issue | 02.04.2020 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 201 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1504/IJEX.2017.10008596 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/34783 | |
dc.identifier.volume | 24 | en_US |
dc.identifier.wos | WOS:000414955200006 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | INDERSCIENCE ENTERPRISES LTD | en_US |
dc.relation.ispartof | INTERNATIONAL JOURNAL OF EXERGY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | irreversibility | en_US |
dc.subject | ejector | en_US |
dc.subject | exergy analysis | en_US |
dc.subject | throttling | en_US |
dc.subject | exergy efficiency | en_US |
dc.title | An experimental investigation on exergy analysis of an ejector expansion refrigeration system | en_US |
dc.type | Article | en_US |