dc.description.abstractIn this study, failure behavior of pre-stressed Glass Fiber Reinforced Plastic (GRP) tubes subjected to low velocity impact was investigated. Filament wound E-glass/epoxy composite tubes with a winding angle of +/- 55 degrees were used in the experiments. The tubes pre-stressed to 32 bars internal pressure, one of the specified operating pressures according to ANSI/AWWA C950 standards. Both prestressed and non-prestressed GRP tubes were subjected to low velocity impact tests at 5, 10 and 15 J low energy levels. Plots of contact force and internal pressure with respect to time and those of force-displacement were obtained and damages occurred on the specimens were examined by means of reflected and transmitted light photography and light microscope. No marked fiber breakages are observed; however, debonding and some sort of delamination on the layers were observed. The GRP tubes with impact damages were subjected to monotonic burst pressures up to failure based on the ASTM D 1599-99 standards. Burst damages on the tubes were studied and variations of their corresponding burst strengths were spotted. Besides that, diameter changes with internal pressures were determined during the tests. Diameter changes with internal pressures for the impacted and the non-impacted tubes were found to be the same. (C) 2014 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipSelcuk University Scientific Research ProjectsSelcuk University [09101030]en_US
dc.description.sponsorshipThis study was carried out as a Ph.D. thesis by Memduh Kara in the Graduate School of Natural and Applied Science at the University of Selcuk, Konya, Turkey. This work was also supported by Selcuk University Scientific Research Projects under Grant Number 09101030.en_US
dc.identifier.doi10.1016/j.compositesb.2014.01.003en_US
dc.identifier.endpage514en_US
dc.identifier.issn1359-8368en_US
dc.identifier.issn1879-1069en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage507en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.compositesb.2014.01.003
dc.identifier.urihttps://hdl.handle.net/20.500.12395/30776
dc.identifier.volume60en_US
dc.identifier.wosWOS:000333506500055en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.relation.ispartofCOMPOSITES PART B-ENGINEERINGen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectPolymer-matrix composites (PMCs)en_US
dc.subjectImpact behavioren_US
dc.subjectMechanical testingen_US
dc.subjectPre-stresseden_US
dc.titleEffect of non-penetrating impact damages of pre-stressed GRP tubes at low velocities on the burst strengthen_US