Perioral electrical burn in children: case report
Küçük Resim Yok
Tarih
2008
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
TURKISH ASSOC TRAUMA EMERGENCY SURGERY
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Perioral electrical burns are rarely seen household injuries that cause both functional and aesthetic deformities requiring special consideration for reconstruction. The cause is usually a child younger than 3 years old biting an electrical cord. An eleven-month-old girl admitted to the emergency room with perioral electrical burn after biting an electrical cable of a television. Her burn area included 60% of the lower lip, down to the mentum, and including left commissure, distal part of the tongue and the floor of the mouth. On the 8th day following the burn, the burned necrotic tissues separated from the healthy living tissues and a bleeding from the labial artery was observed. To reconstruct the lip defect, an inferior-based nasolabial flap from the lateral side was used. The mucosa of the flap was dissected and advanced to form the lower lip vermillion. With this case presentation, the principles and options for perioral electrical burns are presented.