Advanced treatment of coking wastewater by conventional and modified fenton processes

dc.contributor.authorGuclu, Dunyamin
dc.contributor.authorSirin, Nazan
dc.contributor.authorSahinkaya, Serkan
dc.contributor.authorSevimli, Mehmet Faik
dc.date.accessioned2020-03-26T18:41:04Z
dc.date.available2020-03-26T18:41:04Z
dc.date.issued2013
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractCoking wastewater contains high a concentration of refractory and toxic compounds to be treated before being discharged into the environment. The water quality usually cannot meet the discharge limits after conventional biological treatment processes. This article initially investigated the treatability of coking wastewater with conventional and modified Fenton processes for advanced treatment of coking wastewater. Based on the experimental results, up to 86% of chemical oxygen demand (COD) and 99.5% of phenol removals were achieved by the conventional Fenton process at original pH 7.8 within 60 min. pH adjustment was not performed due to the sudden drop in the original pH value, after the addition of Fenton's reagents. A modified Fenton process yielded comparable COD (82%) and phenol (98.5%) removals within 120 min at pH 3.0. The optimal operating conditions were determined as [Fe2+] = 300 mg/L, [H2O2] = 4000 mg/L, and pH = 7.8 for a conventional Fenton process, and [Fe0] = 300 mg/L, [H2O2] = 4500 mg/L, and pH = 3 for a modified Fenton process. (c) 2011 American Institute of Chemical Engineers Environ Prog, 32: 176-180, 2013en_US
dc.description.sponsorshipSelcuk University Scientific Research Fund (S.U. BAP)Selcuk Universityen_US
dc.description.sponsorshipThe authors are grateful for kind financial support provided by Selcuk University Scientific Research Fund (S.U. BAP).en_US
dc.identifier.doi10.1002/ep.10626en_US
dc.identifier.endpage180en_US
dc.identifier.issn1944-7442en_US
dc.identifier.issn1944-7450en_US
dc.identifier.issue2en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage176en_US
dc.identifier.urihttps://dx.doi.org/10.1002/ep.10626
dc.identifier.urihttps://hdl.handle.net/20.500.12395/29201
dc.identifier.volume32en_US
dc.identifier.wosWOS:000317851600002en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.relation.ispartofENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectcoking wastewateren_US
dc.subjectFenton processen_US
dc.subjectzero valent ironen_US
dc.subjectCODen_US
dc.subjectphenolen_US
dc.titleAdvanced treatment of coking wastewater by conventional and modified fenton processesen_US
dc.typeArticleen_US