Electrical characterization of PEDOT:PSS beyond humidity saturation
dc.contributor.author | Kus, Mahmut | |
dc.contributor.author | Okur, Salih | |
dc.date.accessioned | 2020-03-26T17:38:31Z | |
dc.date.available | 2020-03-26T17:38:31Z | |
dc.date.issued | 2009 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | PEDOT:PSS humidity sensor was fabricated using a drop-casting method between thermally evaporated gold electrodes with 30 mu m separation and 300 mu m channel width on a glass substrate. AC, DC resistivity, and AFM techniques were used to characterize the PEDOT: PSS humidity sensor in the same environmental conditions. The change of resistivity was monitored with increasing relative humidity (RH) up to 90%. The resistivity increases linearly up to a maximum value, and then it starts to decrease abruptly above 80% relative humidity (RH) after saturation of water uptake. The decrease in resistivity above 80% RH seems to be due to the water meniscus layer formed on the saturated PEDOT: PSS film. Below 80% RH, the device works like a humidity sensor. (C) 2009 Elsevier B.V. All rights reserved. | en_US |
dc.description.sponsorship | TUBITAK (Scientific and Technical Research Council of Turkey)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [TBAG108T718]; Turkish State Planning Organization (DPT)Turkiye Cumhuriyeti Kalkinma Bakanligi [DPT2003K120390] | en_US |
dc.description.sponsorship | This research is supported by TUBITAK (Scientific and Technical Research Council of Turkey) with the project number of TBAG108T718 and by Turkish State Planning Organization (DPT) with the research project number of DPT2003K120390. | en_US |
dc.identifier.doi | 10.1016/j.snb.2009.08.055 | en_US |
dc.identifier.endpage | 181 | en_US |
dc.identifier.issn | 0925-4005 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 177 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.snb.2009.08.055 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/23504 | |
dc.identifier.volume | 143 | en_US |
dc.identifier.wos | WOS:000272376800028 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER SCIENCE SA | en_US |
dc.relation.ispartof | SENSORS AND ACTUATORS B-CHEMICAL | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Humidity sensors | en_US |
dc.subject | PEDOT:PSS | en_US |
dc.subject | Resistivity | en_US |
dc.subject | Conducting polymer | en_US |
dc.title | Electrical characterization of PEDOT:PSS beyond humidity saturation | en_US |
dc.type | Article | en_US |