EFFECT OF INTERRUPTED BORIDING ON MICROSTRUCTURE AND MECHANICAL PROPERTIES OF 16MnCr5 STEELS
dc.contributor.author | Calik, A. | |
dc.contributor.author | Ucar, N. | |
dc.contributor.author | Kocaslan, A. | |
dc.contributor.author | Karakas, S. | |
dc.date.accessioned | 2020-03-26T19:53:32Z | |
dc.date.available | 2020-03-26T19:53:32Z | |
dc.date.issued | 2018 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | The microstructure, microhardness and tensile properties of continuously borided and interrupted borided 16MnCr5 steel were compared. In the continuous process, boriding was carried out continuously at 1273 K for 16 h. In the interrupted process, after 5 h of boriding at 1273 K, the crucible containing the specimens and the boriding powders was removed from the furnace and cooled to 873 K in still air for 30 min and this procedure was repeated three times. Both boriding treatments were achieved in a solid medium using the powder pack method with commercial Ekabor-I powders as the boron source. X-ray diffraction studies indicated the presence of FeB and Fe2B phases in the boride layers for both boriding treatments. The transition zone was more pronounced in the continuously borided steel. The average hardness values of the boride layers were 1759 and 1648HV(0.1) for the continuously borided and interrupted borided steels, respectively. The hardness of the boride layers were considerably higher than the 200HV(0.1) hardness of the untreated steel. No significant difference in tensile properties could be observed between the two different boriding procedures. | en_US |
dc.description.sponsorship | Scientific Research Projects Coordination Unit of Suleyman Demirel UniversitySuleyman Demirel University [SDU-BAP 4027-YL1-14] | en_US |
dc.description.sponsorship | This study was supported by the Scientific Research Projects Coordination Unit of Suleyman Demirel University (Project reference number: SDU-BAP 4027-YL1-14). | en_US |
dc.identifier.doi | 10.1142/S0218625X19500227 | en_US |
dc.identifier.issn | 0218-625X | en_US |
dc.identifier.issn | 1793-6667 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1142/S0218625X19500227 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/36532 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wos | WOS:000448273900016 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | WORLD SCIENTIFIC PUBL CO PTE LTD | en_US |
dc.relation.ispartof | SURFACE REVIEW AND LETTERS | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Interrupted boriding | en_US |
dc.subject | tensile strength | en_US |
dc.subject | hardness | en_US |
dc.subject | transition zone | en_US |
dc.subject | surface hardening | en_US |
dc.title | EFFECT OF INTERRUPTED BORIDING ON MICROSTRUCTURE AND MECHANICAL PROPERTIES OF 16MnCr5 STEELS | en_US |
dc.type | Article | en_US |