Özdeş İki Spektrofotometrenin Cihazlar Arası Güvenilirlik Ve Tekrarlanabilirliğinin İncelenmesi

dc.authorid0000-0002-6516-276Xen_US
dc.authorid0000-0002-8897-3928en_US
dc.authorid0000-0002-6114-3369en_US
dc.contributor.authorSavaş, Abdulhaluk
dc.contributor.authorTunçdemir, Ali Rıza
dc.contributor.authorSavaş, Tuba Yılmaz
dc.date.accessioned2023-01-18T08:35:39Z
dc.date.available2023-01-18T08:35:39Z
dc.date.issued2021en_US
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAmaç: Bu in-vitro çalışmanın amacı, farklı yazılımlara sahip özdeş iki spektrofotometrenin tekrarlanabilirliğini ve cihazlar arası güvenilirliğini değerlendirmektir. Gereç ve Yöntemler: Bir renk skalasına (Vita 3D-Master, Vita Zahnfabrik) ait 26 adet renk tabı, farklı yazılımlara sahip (v509i: A cihazı, v505p: B cihazı) iki özdeş spektrofotometre (Vita EasyShade V) ile ölçüldü ve CIELab değerleri kaydedildi (n=260). Spektrofotometrelerin ölçümleri arasındaki renk farkları (?E00) hesaplandı. Tekrarlanabilirlik değerlendirilmesi için aynı skalanın 3M2 renk tabı, iki spektrofotometre ile ölçüldü (n=50). Cihazların skala ile renk eşleştirme doğruluk oranı hesaplandı. Cihazlar arası güvenilirlik ve cihazlar arasındaki ölçüm farkları, sınıf içi korelasyon katsayısı (ICC), Cronbach’s alfa ve Paired T-testi kullanılarak hesaplandı (?=0.05). Bulgular: Cihazlar arası güvenilirlik L*, a* ve b* parametreleri için yüksek düzeyde bulunmuştur (ICC>0.99). Renk skalasının ?E00 değerleri 0.21 ile 1.78 arasında değişmektedir ve skaladaki bütün renklerin ?E00 değerleri kabul edilebilirlik eşik değerinin altındadır (?E00<1.8). A cihazının ortalama L* değeri B cihazından önemli derecede yüksek (P<0.001), ortalama a* ve b* değerleri ise önemli derecede düşük bulunmuştur (P<0.001). Tekrarlanabilirlik her iki cihazda a* ve b* parametresi için mükemmel (SD<0.1), L* parametresi için ise biraz daha düşüktür (0.15<SD<0.25). Her iki cihazın skala ile renk eşleştirme doğruluk oranı % 34.6 olarak hesaplanmıştır. Sonuç: İki özdeş spektrofotometrenin cihazlar arası güvenilirliği ve tekrarlanabilirliği yüksek; renk farkı değerleri ise kabul edilebilir düzeyde bulunmuştur. Ancak her iki cihaz, aynı renk skalası için farklı L*, a* ve b* değeri ölçümü yapabilmektedir.en_US
dc.description.abstractBackground: The purpose of this in-vitro study was to evaluate the repeatability and interdevice reliability of two identical spectrophotometers with different software. Methods: Twenty-six shade tabs of a shade guide (Vita 3D-Master, Vita Zahnfabrik) were measured with two identical spectrophotometers (Vita EasyShade V) with different software (v509i: Device A; v505p: Device B), and CIELab values were recorded (n=260). The color difference (?E00) values between measurements of spectrophotometers were calculated. For repeatability, the 3M2 shade tab of the same shade guide was measured 50 times with each spectrophotometer. The matching accuracy rate of the devices with shade guide was calculated. Interdevice reliability and differences between devices were calculated using intraclass correlation coefficient (ICC), Cronbach's alpha, and Paired T-test (?=0.05). Results: Interdevice reliability was found to be high for L*, a*, and b* parameters (ICC>0.99). The ?E00 values of the shade tabs range from 0.21 to 1.78, which were lower than the acceptability threshold (?E00<1.8). The mean L* value of Device A was significantly higher than that of Device B (P<0.001), while the mean a* and b* values were significantly lower (P<0.001). The repeatability is excellent for a* and b* parameters (SD<0.1), however, slightly lower for the L* (0.15<SD<0.25) in both devices. The matching accuracy rates of both devices were calculated as 34.6 %. Conclusion: The reliability and repeatability of two identical spectrophotometers were found to be high, and the color difference values were found to be at an acceptable level. However, both devices can display different L*, a*, and b* values for the same shade guideen_US
dc.identifier.citationSavaş, T. Y., Savaş, A., Tunçdemir, A. R., (2021). Özdeş İki Spektrofotometrenin Cihazlar Arası Güvenilirlik Ve Tekrarlanabilirliğinin İncelenmesi. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 8 (3), 605-610. Doi: 10.15311/selcukdentj.1009775en_US
dc.identifier.doi10.15311/selcukdentj.1009775en_US
dc.identifier.endpage610en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue3en_US
dc.identifier.startpage605en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/44892
dc.identifier.volume8en_US
dc.institutionauthorSavaş, Tuba Yılmaz
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectCihaz hatası analizien_US
dc.subjectGüvenilirliken_US
dc.subjectRenken_US
dc.subjectSpektrofotometrien_US
dc.subjectTekrarlanabilirliken_US
dc.subjectColoren_US
dc.subjectEquipment failure analysisen_US
dc.subjectReliabilityen_US
dc.subjectRepeatabilityen_US
dc.subjectSpectrophotometryen_US
dc.titleÖzdeş İki Spektrofotometrenin Cihazlar Arası Güvenilirlik Ve Tekrarlanabilirliğinin İncelenmesien_US
dc.title.alternativeEvaluation of Interdevice Reliability and Repeatability of Two Identical Spectrophotometersen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2.pdf
Boyut:
750.15 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: