Effect of disinfection on the dimensional stability of polyether impression materials: Basic science research

dc.contributor.authorYilmaz H.
dc.contributor.authorAydin C.
dc.contributor.authorGul B.
dc.contributor.authorYilmaz C.
dc.contributor.authorSemiz M.
dc.date.accessioned2020-03-26T17:19:11Z
dc.date.available2020-03-26T17:19:11Z
dc.date.issued2007
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractPurpose: Difficulties in sterilizing impressions have led to chemical disinfection solutions as an alternative; however, some impression materials are more sensitive to humidity. For example, polyether impression materials are more hydrophilic. This study investigated the effect of three disinfecting methods on the dimensional stability of three polyether impression materials. Materials and Methods: Three polyether impression materials (P2, Impregum Penta Soft, and Impregum Penta) were submitted to the following treatments: spray disinfectant (Mikrozid Liquid), immersion in 2% glutaraldehyde solution (Super-On), immersion in 0.525% sodium hypochlorite solution for 10 minutes, and a control group (not disinfected). Each group included five samples. After treatment, dimensional change was evaluated according to ISO 4823. The data were analyzed by 2-way analysis of variance at ? = 0.05. Results: The mean percentages of linear dimensional change of materials P2, Penta Soft, and Penta were -0.040%, 0.098%, and 0.100%, respectively. The dimensional change associated with different disinfectant agents mikrozid liquid, 2% glutaraldehyde, room air (control), and 0.525% sodium hypochlorite was 0.013%, 0.024%, 0.077%, and 0.096%, respectively. The interaction between the impression materials and the disinfectant treatment was not significant. The disinfectant agents can be classified in two groups as low- and high-effected. The control group did not significantly differ from either group. Conclusion: From the standpoint of dimensional change, the disinfectants tested for 10 minutes caused no significant linear dimensional change in the polyether impression materials, compared with the control group. J Prosthodont 2007;16:473-479. Copyright © 2007 by The American College of Prosthodontists.en_US
dc.identifier.doi10.1111/j.1532-849X.2007.00235.xen_US
dc.identifier.endpage479en_US
dc.identifier.issn1059941Xen_US
dc.identifier.issue6en_US
dc.identifier.pmid17760866en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage473en_US
dc.identifier.urihttps://dx.doi.org/10.1111/j.1532-849X.2007.00235.x
dc.identifier.urihttps://hdl.handle.net/20.500.12395/21823
dc.identifier.volume16en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Prosthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectDimensional stabilityen_US
dc.subjectDisinfectionen_US
dc.subjectImpression materialsen_US
dc.subjectPolyethersen_US
dc.titleEffect of disinfection on the dimensional stability of polyether impression materials: Basic science researchen_US
dc.typeArticleen_US

Dosyalar